citation |
- title:
- Ground based in situ observations of steel_canister at Illmitz (AT0002R)
- dates:
- fileIdentifier:
- EBAS/AT0002R.20220712130000.20230309132655.steel_canister..air.6d.1d.DE20L_SilcoCan_at02.DE20L_FZJ_CFKADS2270_IMP_2022.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Data license": "https://creativecommons.org/licenses/by/4.0/",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "AT0002R.20220712130000.20230309132655.steel_canister..air.6d.1d.DE20L_SilcoCan_at02.DE20L_FZJ_CFKADS2270_IMP_2022.lev2.nc",
"File creation": "2023-03-09T16:28:18.397755 UTC",
"Export state": "2023-03-09T15:35:03.979862 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20220712130000",
"Revision date": "20230309132655",
"Version": "1",
"Version description": "initial",
"Data level": "2",
"Period code": "6d",
"Resolution code": "1d",
"Station code": "AT0002R",
"Platform code": "AT0002S",
"Station name": "Illmitz",
"Station GAW-ID": "ILL",
"Station GAW-Name": "Illmitz",
"Station land use": "Grassland",
"Station setting": "Rural",
"Station latitude": "47.7666664124",
"Station longitude": "16.7666664124",
"Station altitude": "117.0 m",
"Measurement height": "0.5 m",
"Regime": "IMG",
"Matrix": "air",
"Laboratory code": "DE20L",
"Instrument type": "steel_canister",
"Instrument name": "SilcoCan_at02",
"Instrument manufacturer": "Restek",
"Instrument model": "SilcoCan",
"Analytical laboratory code": "DE20L",
"Analytical measurement technique": "crds",
"Analytical instrument name": "FZJ_CFKADS2270_IMP_2022",
"Analytical instrument manufacturer": "Picarro",
"Analytical instrument model": "G2401",
"Analytical instrument serial number": "CFKADS2270",
"Method ref": "DE20L_FZJ_CFKADS2270_IMP_2022",
"Inlet type": "Canister valve opening",
"Inlet description": "Silcosteel capillary with Na2S2O3 filter for ozone destruction after Helmig at al",
"Detection limit expl.": "Detection limit equals 3 times the precision",
"Measurement uncertainty expl.": "Includes reproducibility (precision) + systematic errors (accuracy). Ref:http://www.atmos-meas-tech.net/8/2715/2015/",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Values below 1 pmol/mol are not reported by the instrument.",
"Organization": "DE20L, Forschungszentrum Jülich, , Institut für Energie- und Klimaforschung: Troposphäre (IEK-8), Wilhelm-Johnen-Straße, , 52425, Juelich, Germany",
"Framework acronym": "CAMPAIGN, EMEP",
"Framework name": ", European Monitoring and Evaluation Programme",
"Framework description": ", The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Wenche Aas, Kjetil Tørseth",
"Framework contact email": "waa@nilu.no, kt@nilu.no",
"Originator": "Wegener, Robert, r.wegener@fz-juelich.de, Forschungszentrum Jülich GmbH, FZJ, Institut for Energy and Climate Research IEK8 Troposphere, , , 52425, Jülich, Germany",
"Submitter": "Wegener, Robert, r.wegener@fz-juelich.de, Forschungszentrum Jülich GmbH, FZJ, Institut for Energy and Climate Research IEK8 Troposphere, , , 52425, Jülich, Germany",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|