citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at TMNT09 Vielsalm (BE0007R) using smps
- dates:
- fileIdentifier:
- EBAS/BE0007R.20130101000000.20160615191436.smps.particle_number_size_distribution.pm10.3y.1h.BE01L_IFT_LDMA_BE02.DE08L_IFT_CL.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "BE0007R.20130101000000.20160615191436.smps.particle_number_size_distribution.pm10.3y.1h.BE01L_IFT_LDMA_BE02.DE08L_IFT_CL.lev2.nc",
"File creation": "20190513090001",
"Startdate": "20130101000000",
"Revision date": "20160615191436",
"Version": "2",
"Version description": "initial revision, Adis_EUSAAR_NRT_DMPS_lev0_2_lev1 v.0.0_4, Adis_EUSAAR_NRT_neph_lev1_2_lev2 v.0.0.5b -- TO BE CONFIRMED",
"Data level": "2",
"Period code": "3y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "BE0007R",
"Platform code": "BE0007S",
"Station name": "TMNT09 Vielsalm",
"Station latitude": "50.304003",
"Station longitude": "6.001271",
"Station altitude": "496.0 m",
"Measurement latitude": "50.304003",
"Measurement longitude": "6.001271",
"Measurement altitude": "496.0 m",
"Measurement height": "3.5 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "BE01L",
"Instrument type": "smps",
"Instrument name": "IFT_LDMA_BE02",
"Instrument manufacturer": "IFT",
"Instrument model": "IFT Long DMA",
"Instrument serial number": "00002",
"Method ref": "DE08L_IFT_CL",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, Digitel, flow 2.3 m3/h",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer operated with reduced pressure sheath air",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.3 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "Uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "BE01L, Flemish Environmental Company, VMM, Section Air, Kronenburgstraat 45, , 2000, Antwerp, Belgium",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Lenartz, Fabian, f.lenartz@issep.be, Institut Scientifique de Service Public, ISSeP, 200, Air Quality, Rue du Chera 200, , 4000 Liege, Belgium",
"Submitter": "Lenartz, Fabian, f.lenartz@issep.be, Institut Scientifique de Service Public, ISSeP, 200, Air Quality, Rue du Chera 200, , 4000 Liege, Belgium",
"Acknowledgement": "Please acknowledge ISSeP and contact either Benjamin Bergmans (b.bergmans@issep.be) or Fabian Lenartz (f.lenartz@issep.be) if you use this data set",
"Comment": "None"
}
|