citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at BEO Moussala (BG0001R) using smps
- dates:
- fileIdentifier:
- EBAS/BG0001R.20170101000000.20200624111550.smps.particle_number_size_distribution.pm10.2y.1h.BG01L_SMPS_IFT.BG01L_TechVal-TROPOS-SMPS-v.1.3.8.37.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "BG0001R.20170101000000.20200624111550.smps.particle_number_size_distribution.pm10.2y.1h.BG01L_SMPS_IFT.BG01L_TechVal-TROPOS-SMPS-v.1.3.8.37.lev2.nc",
"File creation": "20200624183453",
"Startdate": "20170101000000",
"Revision date": "20200624111550",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "BG0001R",
"Platform code": "BG0001S",
"Station name": "BEO Moussala",
"Station latitude": "42.166667",
"Station longitude": "23.583333",
"Station altitude": "2971.0 m",
"Measurement latitude": "42.178753",
"Measurement longitude": "23.585428",
"Measurement altitude": "2925.0 m",
"Measurement height": "7.5 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "BG01L",
"Instrument type": "smps",
"Instrument name": "SMPS_IFT",
"Instrument manufacturer": "TROPOS",
"Instrument model": "TROPOS-SMPS",
"Instrument serial number": "SMPS_Usti",
"Method ref": "BG01L_TechVal-TROPOS-SMPS-v.1.3.8.37",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Whole-air inlet",
"Inlet description": "flow 30.00 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer (1/4\" in diameter)",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "715.00 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "BG01L, \"Institute for Nuclear Research and Nuclear Energy, Basic Environmental Observatory Moussala\", , , \"72 Tsarigradsko Chaussee Blvd, 1784-Sofia, Bulgaria\", , , , ",
"Frameworks": "ACTRIS",
"Originator": "Kalapov, Ivo, , , , , , , , , ",
"Submitter": "Arsov, Todor, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|