citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Mount Chacaltaya (BO0001R) using smps
- dates:
- fileIdentifier:
- EBAS/BO0001R.20120101000000.20200402012333.smps.particle_number_size_distribution.aerosol.8y.1h.BO01L_SMPS_UMSA-LAP_CHACALTAYA_BOLIVIA.DE08L_TROPOS_CL_SMPS.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "BO0001R.20120101000000.20200402012333.smps.particle_number_size_distribution.aerosol.8y.1h.BO01L_SMPS_UMSA-LAP_CHACALTAYA_BOLIVIA.DE08L_TROPOS_CL_SMPS.lev2.nc",
"File creation": "20200406183453",
"Startdate": "20120101000000",
"Revision date": "20200402012333",
"Version": "1",
"Version description": "initial revision, DMPS_control_lev2 v.0.0_1",
"Data level": "2",
"Period code": "8y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "BO0001R",
"Platform code": "BO0001S",
"Station name": "Mount Chacaltaya",
"Station latitude": "-16.2000007629",
"Station longitude": "-68.0999984741",
"Station altitude": "5320.0 m",
"Measurement latitude": "-16.35",
"Measurement longitude": "-68.13",
"Measurement altitude": "5240.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "aerosol",
"Laboratory code": "BO01L",
"Instrument type": "smps",
"Instrument name": "SMPS_UMSA-LAP_CHACALTAYA_BOLIVIA",
"Instrument manufacturer": "TROPOS",
"Instrument model": "TROPOS-SMPS",
"Instrument serial number": "SMPS-CHACALTAYA_BOLIVIA",
"Method ref": "DE08L_TROPOS_CL_SMPS",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Whole-air inlet",
"Inlet description": "Automatic heater dryer which is activated for Relative Humidity great than 90%, flow 162.00 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer (1/4\" in diameter)",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012. (AMT)",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "BO01L, \"Atmospheric Physics Laboratory, ALP, UMSA, Campus Cota Cota calle 27, Endifico FCPN piso 3, , La Paz, Bolivia\", , , , , , , ",
"Frameworks": "ACTRIS GAW-WDCA GUAN",
"Originator": "Zaratti, Francesco, fzaratti@umsa.bo, Laboratory for Atmospheric Physics, LAP, , Campus Cota Cota calle 27 FCPN Building piso 3, , 4680, La Paz, Bolivia",
"Submitter": "Velarde, Fernando, fvelarde@chacaltaya.edu.bo, Laboratory for Atmospheric Physics, LAP, , Campus Cota Cota calle 27 FCPN Building piso 3, , 4680, La Paz, Bolivia",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|