citation |
- title:
- Ground based in situ observations of low_vol_sampler at Toronto (CA0106U)
- dates:
- fileIdentifier:
- EBAS/CA0106U.20061017150500.20170920165600.low_vol_sampler..pm25.9y.1w.CA09L_EC_lvs1_TOR.CA09L_OCEC_Carbon_Aerosol_Analyzer.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "CA0106U.20061017150500.20170920165600.low_vol_sampler..pm25.9y.1w.CA09L_EC_lvs1_TOR.CA09L_OCEC_Carbon_Aerosol_Analyzer.lev2.nc",
"File creation": "20190513092431",
"Startdate": "20061017150500",
"Revision date": "20170920165600",
"Version": "1",
"Version description": "Initial revision, manually inspected",
"Data level": "2",
"Period code": "9y",
"Resolution code": "1w",
"Sample duration": "1w",
"Orig. time res.": "1w",
"Station code": "CA0106U",
"Platform code": "CA0106S",
"Station name": "Toronto",
"Station WDCA-ID": "GAWACAONTOT",
"Station GAW-ID": "TOT",
"Station GAW-Name": "Toronto",
"Station other IDs": "TORONTO(NDACC)",
"Station state/province": "ON",
"Station land use": "Urban park",
"Station setting": "Urban and center city",
"Station GAW type": "R",
"Station WMO region": "4",
"Station latitude": "43.7833328247",
"Station longitude": "-79.4666671753",
"Station altitude": "198.0 m",
"Measurement altitude": "198.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "ug C/m3",
"Matrix": "pm25",
"Laboratory code": "CA09L",
"Instrument type": "low_vol_sampler",
"Instrument name": "EC_lvs1_TOR",
"Instrument manufacturer": "ECCC_CAIR Lab",
"Instrument model": "LVS1",
"Instrument serial number": "TOR_01",
"Method ref": "CA09L_OCEC_Carbon_Aerosol_Analyzer",
"Standard method": "SOP=EnCan_Total_900",
"Inlet type": "Cyclone",
"Inlet description": "Downward facing with rain shield",
"Medium": "Quartz",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "Temperature controlled",
"Humidity/temperature control description": "Filter holder kept in a closure with temperature range of 16 ° - 26 ° C.",
"Detection limit": "0.001 ug C/m3",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of analytical blanks divided by the mean sampling volume. The mean of analytical blanks is 0.03 ugC/cm2 and the mean sampling air volume is 155 m3",
"Measurement uncertainty expl.": "calculated based on error propagation from the uncertainties of analytical instrument, filter's exposure area, sampling volume, field blanks and inhomogeneity of samples. It is similar to the example by Jean-Philippe Putaud on WDC site",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "zero values reported as measured if blank correction is applied, which may cause the value to become negative. No negative values are allowed",
"Organization": "CA09L, Environment & Climate Change Canada, ECCC/S&T/CRD, Science and Technology Branch /Climate Research Division, 4905 Dufferin Street, , M3H 5T4, \"Toronto, Ontario\", Canada",
"Frameworks": "GAW-WDCA",
"Originator": "Huang, Lin, Lin.Huang@Canada.ca, Environment and Climate Change Canada, S & T Branch, Climate Research Division, CCMR, Dufferin Street, M3H 5T4, Toronto, Canada",
"Submitter": "Huang, Lin, Lin.Huang@Canada.ca, Environment and Climate Change Canada, S & T Branch, Climate Research Division, CCMR, Dufferin Street, M3H 5T4, Toronto, Canada",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Concentration corrected to calibrated flow rate, based annual flow calibrations carried out by primary methods (e.g., Gilibrator or Bios Definer 220-H)"
}
|