citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Jungfraujoch (CH0001G) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/CH0001G.20030101000000.20190603130025.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.12y.1h.CH02L_Carusso_MAAP_42545_15_No011.CH02L_MAAP_abs_coef.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "CH0001G.20030101000000.20190603130025.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.12y.1h.CH02L_Carusso_MAAP_42545_15_No011.CH02L_MAAP_abs_coef.lev2.nc",
"File creation": "20190604082608",
"Startdate": "20030101000000",
"Revision date": "20190603130025",
"Version": "1",
"Version description": "revision, SPT level 2",
"Data level": "2",
"Period code": "12y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1h",
"Station code": "CH0001G",
"Platform code": "CH0001S",
"Station name": "Jungfraujoch",
"Station GAW-ID": "JFJ",
"Station latitude": "46.5475",
"Station longitude": "7.985",
"Station altitude": "3578.0 m",
"Measurement latitude": "46.55",
"Measurement longitude": "7.99",
"Measurement altitude": "3580.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "CH02L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "Carusso_MAAP_42545_15_No011",
"Instrument manufacturer": "Thermo",
"Instrument model": "5012",
"Instrument serial number": "No011",
"Method ref": "CH02L_MAAP_abs_coef",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "TSP at heated inlet, Digitel, flow >100 l/min",
"Humidity/temperature control": "Other (see metadata)",
"Humidity/temperature control description": "Heated inlet. Sample dried to below 20% RH due to the heated inlet",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "5.0 1/Mm",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values may appear due to statistical variations at very low concentrations",
"Organization": "CH02L, Paul Scherrer Institut, PSI, Laboratory of Atmospheric Chemistry (LAC), OFLB, , 5232, Villigen PSI, Switzerland",
"Frameworks": "ACTRIS EMEP GAW-WDCA",
"Originator": "Weingartner, Ernest, , , , , , , , , ",
"Submitter": "Collaud Coen, Martine, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Standard method: Mass absorption efficiency = 6.6 m2/g. The applied STP correction takes into account a mean T=25°C and a mean P=655 hPa at the station lab."
}
|