citation |
- title:
- Ground based in situ observations of online_gc at Jungfraujoch (CH0001G)
- dates:
- fileIdentifier:
- EBAS/CH0001G.20110101000500.20180208000000.online_gc..air.6y.2h.CH01L_Agilent_GC-MS-MEDUSA_Medusa-12_JFJ.CH01L_VOC_AIR_MEDUSA-12.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "CH0001G.20110101000500.20180208000000.online_gc..air.6y.2h.CH01L_Agilent_GC-MS-MEDUSA_Medusa-12_JFJ.CH01L_VOC_AIR_MEDUSA-12.lev2.nc",
"File creation": "20201008182729",
"Startdate": "20110101000500",
"Revision date": "20180208000000",
"Data level": "2",
"Period code": "6y",
"Resolution code": "2h",
"Sample duration": "20mn",
"Orig. time res.": "2h",
"Station code": "CH0001G",
"Platform code": "CH0001S",
"Station name": "Jungfraujoch",
"Station GAW-ID": "JFJ",
"Station latitude": "46.5475",
"Station longitude": "7.985",
"Station altitude": "3578.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "CH01L",
"Instrument type": "online_gc",
"Instrument name": "Agilent_GC-MS-MEDUSA_Medusa-12_JFJ",
"Instrument manufacturer": "AGAGE+Agilent+Agilent",
"Instrument model": "MEDUSA+6890N+5975B",
"Instrument serial number": "Medusa-12",
"Method ref": "CH01L_VOC_AIR_MEDUSA-12",
"Standard method": "None",
"Calibration scale": "NPL",
"Inlet type": "Hat or hood",
"Inlet description": "above the roof",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty expl.": "Includes reproducibility (precision) + systematic errors (accuracy)",
"Zero/negative values code": "Zero/negative impossible",
"Organization": "CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland",
"Originator": "Vollmer, Martin K., martin.vollmer@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Submitter": "Hill, Matz, matthias.hill@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "No SOP currently available, MEDUSA. Sample volume: 2L, trap at -170degC, trap material Hayesep D, Nafion dryer, no O3 removal, 2-hourly calibration interval"
}
|