citation |
- title:
- Ground based in situ observations of nephelometer at Jungfraujoch (CH0001G)
- dates:
- fileIdentifier:
- EBAS/CH0001G.20140101000000.20200527200157.nephelometer..aerosol.1y.1h.CH02L_TSI_3563_JFJ_dry.CH02L_Neph_3563.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "CH0001G.20140101000000.20200527200157.nephelometer..aerosol.1y.1h.CH02L_TSI_3563_JFJ_dry.CH02L_Neph_3563.lev2.nc",
"File creation": "20200528022916",
"Startdate": "20140101000000",
"Revision date": "20200527200157",
"Version": "1",
"Version description": "Version numbering not tracked, generated by data.aggregate.ebas r4437",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "CH0001G",
"Platform code": "CH0001S",
"Station name": "Jungfraujoch",
"Station GAW-ID": "JFJ",
"Station latitude": "46.5475",
"Station longitude": "7.985",
"Station altitude": "3578.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "CH02L",
"Instrument type": "nephelometer",
"Instrument name": "TSI_3563_JFJ_dry",
"Instrument manufacturer": "TSI",
"Instrument model": "3563",
"Instrument serial number": "1043",
"Method ref": "CH02L_Neph_3563",
"Standard method": "cal-gas=CO2+AIR_truncation-correction=Anderson1998",
"Inlet type": "Hat or hood",
"Inlet description": "Heated total aerosol inlet (25 degC), collects aerosols and hydrometeors smaller than 40 micrometers",
"Humidity/temperature control": "Other (see metadata)",
"Humidity/temperature control description": "Heated inlet. Sample dried to below 20% RH due to the heated inlet",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.2 1/Mm",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used. 0.2 1/Mm for scattering coef at 550m, and 0.1 1/Mm for backscattering coef at 550 nm (Anderson & Ogren 1996)",
"Measurement uncertainty expl.": "Average value taken from Anderson et al. 1996 for statistical and calibration uncertainty",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "CH02L, Paul Scherrer Institut, PSI, Laboratory of Atmospheric Chemistry (LAC), OFLB, , 5232, Villigen PSI, Switzerland",
"Frameworks": "ACTRIS EMEP GAW-WDCA",
"Originator": "Baltensperger, Urs, , , , , , , , , ",
"Submitter": "Bukowiecki, Nicolas, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Adjustments to STP used Sample-T=25C, Sample-P=650hPa"
}
|