citation |
- title:
- Ground based in situ observations of high_vol_sampler at Payerne (CH0002R)
- dates:
- fileIdentifier:
- EBAS/CH0002R.20180101000000.20211021084842.high_vol_sampler..pm25.3y.1d.CH01L_digitel_22.CH01L_EUSAAR2.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "CH0002R.20180101000000.20211021084842.high_vol_sampler..pm25.3y.1d.CH01L_digitel_22.CH01L_EUSAAR2.lev2.nc",
"File creation": "2021-10-21T16:29:03.241907 UTC",
"Export state": "2021-10-21T15:25:02.403000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20180101000000",
"Revision date": "20211021084842",
"Data level": "2",
"Period code": "3y",
"Resolution code": "1d",
"Sample duration": "1d",
"Station code": "CH0002R",
"Platform code": "CH0002S",
"Station name": "Payerne",
"Station latitude": "46.813056",
"Station longitude": "6.944722",
"Station altitude": "489.0 m",
"Measurement height": "5.2 m",
"Regime": "IMG",
"Unit": "ug C/m3",
"Matrix": "pm25",
"Laboratory code": "CH01L",
"Instrument type": "high_vol_sampler",
"Instrument name": "digitel_22",
"Instrument manufacturer": "DIGITEL",
"Instrument model": "DA-80",
"Analytical laboratory code": "CH01L",
"Analytical measurement technique": "thermal-optical_analysis",
"Analytical instrument manufacturer": "Sunset Laboratory",
"Method ref": "CH01L_EUSAAR2",
"Standard method": "TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Flow rate": "500.0 l/min",
"Filter face velocity": "54.0 cm/s",
"Exposed filter area": "153.94 cm2",
"Filter description": "PALLFLEX XP56 Tissuquartz 2500QAT-UP",
"Medium": "Quartz",
"Filter prefiring": "Not prefired",
"Filter conditioning": "293.15 K, 50.0 %RH, 96.0 h",
"Blank correction": "Not blank corrected",
"Artifact correction": "None",
"Charring correction": "By laser transmission",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "From running a number of true instrument blanks, averaging, getting standard deviation, and then multiplying by two. The value is 0.2 ug/sq cm.",
"QA1 measure ID": "ECAC-OCEC-2018-1",
"QA1 date": "2018-04-01 UTC",
"QA1 document name": "Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC-2018-1)",
"QA1 document URL": "http://www.actris-ecac.eu/files/ECAC-report-OCEC-2018-1.pdf",
"Organization": "CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland",
"Framework acronym": "EMEP, ACTRIS",
"Framework name": "European Monitoring and Evaluation Programme, European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.",
"Framework contact name": "Kjetil Tørseth, Cathrine Lund Myhre",
"Framework contact email": "kt@nilu.no, clm@nilu.no",
"Originator": "Hueglin, Christoph, , , , , , , , , ",
"Submitter": "Seitz, Thomas, , , , , , , , , "
}
|