citation |
- title:
- Ground based in situ observations of high_vol_sampler at Rigi (CH0005R)
- dates:
- fileIdentifier:
- EBAS/CH0005R.20160101000000.20201029094057.high_vol_sampler..pm25.2y.1d.CH01L_digitel_52.CH01L_EUSAAR2.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "CH0005R.20160101000000.20201029094057.high_vol_sampler..pm25.2y.1d.CH01L_digitel_52.CH01L_EUSAAR2.lev2.nc",
"File creation": "20201029113931",
"Startdate": "20160101000000",
"Revision date": "20201029094057",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1d",
"Sample duration": "1d",
"Station code": "CH0005R",
"Platform code": "CH0005S",
"Station name": "Rigi",
"Station GAW-ID": "RIG",
"Station latitude": "47.0675",
"Station longitude": "8.463889",
"Station altitude": "1031.0 m",
"Measurement height": "5.4 m",
"Regime": "IMG",
"Unit": "ug C/m3",
"Matrix": "pm25",
"Laboratory code": "CH01L",
"Instrument type": "high_vol_sampler",
"Instrument name": "digitel_52",
"Instrument manufacturer": "DIGITEL",
"Instrument model": "DA-80",
"Analytical laboratory code": "CH01L",
"Analytical measurement technique": "thermal-optical_analysis",
"Analytical instrument name": "OCEC_Lab_Instrument_Model_4L",
"Analytical instrument manufacturer": "Sunset Laboratory",
"Analytical instrument model": "OCEC Lab Instrument Model 4L",
"Method ref": "CH01L_EUSAAR2",
"Standard method": "TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Flow rate": "500.0 l/min",
"Filter face velocity": "54.0 cm/s",
"Exposed filter area": "153.94 cm2",
"Filter description": "PALLFLEX XP56 Tissuquartz 2500QAT-UP",
"Medium": "Quartz",
"Filter prefiring": "Not prefired",
"Filter conditioning": "293.15 K, 50.0 %, 96.0 h",
"Blank correction": "Not blank corrected",
"Artifact correction": "None",
"Charring correction": "By laser transmission",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "For OC, not for EC; Determined by taking 3 times standard deviation of ensemble of field blanks",
"QA1 measure ID": "ECAC-OCEC-2016-2",
"QA1 date": "20161001",
"QA1 document name": "Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC-2016-2)",
"QA1 document URL": "http://www.actris-ecac.eu/files/OCEC-2016-2-REPORT.pdf",
"Organization": "CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Hueglin, Christoph, , , , , , , , , ",
"Submitter": "Seitz, Thomas, , , , , , , , , "
}
|