citation |
- title:
- Ground based in situ observations of online_gc at Rigi (CH0005R)
- dates:
- fileIdentifier:
- EBAS/CH0005R.20160101002300.20180718060000.online_gc..air.2y.2h.CH01L_Agilent_ADS-GC-FID_cn10450060_RIG.CH01L_ADS_GC_FID_VOCAIR_RIGI.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "CH0005R.20160101002300.20180718060000.online_gc..air.2y.2h.CH01L_Agilent_ADS-GC-FID_cn10450060_RIG.CH01L_ADS_GC_FID_VOCAIR_RIGI.lev2.nc",
"File creation": "20190513095835",
"Startdate": "20160101002300",
"Revision date": "20180718060000",
"Data level": "2",
"Period code": "2y",
"Resolution code": "2h",
"Sample duration": "40mn",
"Orig. time res.": "40mn",
"Station code": "CH0005R",
"Platform code": "CH0005S",
"Station name": "Rigi",
"Station GAW-ID": "RIG",
"Station latitude": "47.0675",
"Station longitude": "8.463889",
"Station altitude": "1031.0 m",
"Measurement altitude": "1034.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "CH01L",
"Instrument type": "online_gc",
"Instrument name": "Agilent_ADS-GC-FID_cn10450060_RIG",
"Instrument manufacturer": "Agilent",
"Instrument model": "6890GC/FID",
"Instrument serial number": "cn10450060",
"Method ref": "CH01L_ADS_GC_FID_VOCAIR_RIGI",
"Standard method": "SOP=ACTRIS_VOC_2014",
"Calibration scale": "NPL",
"Calibration standard ID": "D292408",
"Inlet type": "Hat or hood",
"Inlet description": "ambient air is brought into the cabin through a main inlet line at a flow rate of 300 lpm. From the main inlet line short stainless steel tubes are used to bring the air samples to the instruments.",
"Detection limit expl.": "Determined by integration of a baseline signal multiplied by a factor of 3",
"Measurement uncertainty expl.": "Includes reproducibility (precision) + systematic errors (accuracy)",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland",
"Frameworks": "ACTRIS EMEP GAW-WDCRG",
"Originator": "Reimann, Stefan, , , , , , , , , ",
"Submitter": "Hill, Matz, matthias.hill@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "No SOP currently available, o3 not removed, nafion dryer, Calibration interval:1/two weeks"
}
|