citation |
- title:
- Ground based in situ observations of ozone at El Tololo (CL0001R) using uv_abs
- dates:
- fileIdentifier:
- EBAS/CL0001R.20130101000000.20211108091352.uv_abs.ozone.air.8y.1h.CL01L_TEI49C_no72417371.CL01L_uv_abs.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "CL0001R.20130101000000.20211108091352.uv_abs.ozone.air.8y.1h.CL01L_TEI49C_no72417371.CL01L_uv_abs.lev2.nc",
"File creation": "2021-11-08T18:07:38.562926 UTC",
"Export state": "2021-11-08T17:25:02.660000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20130101000000",
"Revision date": "20211108091352",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "8y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "CL0001R",
"Platform code": "CL0001S",
"Station name": "El Tololo",
"Station WDCA-ID": "GAWACL__TLL",
"Station GAW-ID": "TLL",
"Station GAW-Name": "El Tololo",
"Station land use": "Desert",
"Station setting": "Mountain",
"Station GAW type": "R",
"Station WMO region": "3",
"Station latitude": "-30.17254",
"Station longitude": "-70.79923",
"Station altitude": "2220.0 m",
"Measurement altitude": "2225.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "CL01L",
"Instrument type": "uv_abs",
"Instrument name": "TEI49C_no72417371",
"Instrument manufacturer": "Thermo",
"Instrument model": "49C",
"Instrument serial number": "no72417371",
"Method ref": "CL01L_uv_abs",
"Standard method": "SOP=GAW_209(2013)",
"Inlet type": "Hat or hood",
"Inlet description": "inlet approx. 2 m above the building and 5 m above the ground; coarse mesh at the top of the inlet to protect against spiders etc.; 47 mm teflon filter (5 micron) just upstream of the instrument inlet.",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "6.35 mm",
"Inlet tube length": "10.0 m",
"Maintenance description": "regular replacements of the inlet filters and check of all instrument parameters.",
"Flow rate": "1.0 l/min",
"Zero/span check type": "manual",
"Humidity/temperature control": "None",
"Absorption cross section": "1.1476e-17 cm2",
"QA1 measure ID": "WCC Empa Site Audit",
"QA1 date": "2017-12-12 UTC",
"QA1 outcome": "pass",
"Organization": "CL01L, Direccion Meteorologica de Chile, Meteochile, , \"Casilla 63 Aeropuerto Int. Arturo Merino Benitez, , , Santiago, Chile\", , , , ",
"Framework acronym": "GAW-WDCRG",
"Framework name": "World Data Centre for Reactive Gases",
"Framework description": "The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Torres, Gaston, , , , , , , , , ",
"Submitter": "Steinbacher, Martin, martin.steinbacher@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|