citation |
- title:
- Ground based in situ observations of online_gc at Cape Verde Atmospheric Observatory (CV0001G)
- dates:
- fileIdentifier:
- EBAS/CV0001G.20180103135653.20190531000000.online_gc..air.1y.2659s.CV01L_Agilent_GC-FID_7890A_G3440A.CV01L_Manual_AIR_only.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "CV0001G.20180103135653.20190531000000.online_gc..air.1y.2659s.CV01L_Agilent_GC-FID_7890A_G3440A.CV01L_Manual_AIR_only.lev2.nc",
"File creation": "2021-01-29T00:31:50.145965 UTC",
"Export state": "2021-01-28T23:25:05.297000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20180103135653",
"Revision date": "20190531000000",
"Version": "2",
"Version description": "first revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "2659s",
"Sample duration": "20mn",
"Orig. time res.": "3261s",
"Station code": "CV0001G",
"Platform code": "CV0001S",
"Station name": "Cape Verde Atmospheric Observatory",
"Station GAW-ID": "CVO",
"Station GAW-Name": "Cape Verde Observatory",
"Station land use": "Gravel and stone",
"Station setting": "Coastal",
"Station GAW type": "G",
"Station WMO region": "1",
"Station latitude": "16.86403",
"Station longitude": "-24.86752",
"Station altitude": "10.0 m",
"Measurement altitude": "10.0 m",
"Measurement height": "10.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "CV01L",
"Instrument type": "online_gc",
"Instrument name": "Agilent_GC-FID_7890A_G3440A",
"Instrument manufacturer": "MARKES+MARKES+Agilent",
"Instrument model": "Air Server+UNITY2+7890A GC/FID",
"Instrument serial number": "CN12191070",
"Method ref": "CV01L_Manual_AIR_only",
"Standard method": "None",
"Calibration scale": "NPL",
"Calibration standard ID": "Manufacturer NPL; Batch D386632",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood, 15m total length, insulated, 1m/s flow",
"Detection limit expl.": "Detection limit equals 3 times the precision",
"Measurement uncertainty expl.": "expanded uncertainity 2 sigma and it includes reproducibility (precision) + systematic error",
"Zero/negative values code": "Zero/negative impossible",
"Organization": "CV01L, National Institute of Meteorology and Geophysics, , , \"Espargos, Ilha do Sal 76\", , , , Cape Verde",
"Framework acronym": "ACTRIS, GAW-WDCRG",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, World Data Centre for Reactive Gases",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Cathrine Lund Myhre, Kjetil Tørseth",
"Framework contact email": "clm@nilu.no, kt@nilu.no",
"Originator": "Carpenter, Lucy, lucy.carpenter@york.ac.uk, National Centre for Atmospheric Science, NCAS, Wolfson Atmospheric Chemistry Laboratories, , Innovation Way, YO10 5DQ, York, Great Britain",
"Submitter": "Punjabi, Shalini, shalini.punjabi@york.ac.uk, National Centre for Atmospheric Science, NCAS, Wolfson Atmospheric Chemistry Laboratories, Innovation Way, , YO10 5DQ, York, Great Britain",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Preconcentration by commercial MARKES unit, o3 removal by heated stainless steel lines , Sterling Coolers and condensing chilllers use for water removal , monthly calibration interval"
}
|