citation |
- title:
- Ground based in situ observations of sulphur_dioxide at Cape Verde Atmospheric Observatory (CV0001G) using uv_fluoresc
- dates:
- fileIdentifier:
- EBAS/CV0001G.20200101000000.20220429000000.uv_fluoresc.sulphur_dioxide.air.2y.1h.GB12L_CVO_SO2_Thermo43series.GB12L_Thermo.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "CV0001G.20200101000000.20220429000000.uv_fluoresc.sulphur_dioxide.air.2y.1h.GB12L_CVO_SO2_Thermo43series.GB12L_Thermo.lev2.nc",
"File creation": "2022-04-29T16:26:51.412782 UTC",
"Export state": "2022-04-29T16:25:02.663000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20200101000000",
"Revision date": "20220429000000",
"Version": "1",
"Version description": "initial data",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "4s",
"Station code": "CV0001G",
"Platform code": "CV0001S",
"Station name": "Cape Verde Atmospheric Observatory",
"Station GAW-ID": "CVO",
"Station GAW-Name": "Cape Verde Observatory",
"Station land use": "Gravel and stone",
"Station setting": "Coastal",
"Station GAW type": "G",
"Station WMO region": "1",
"Station latitude": "16.86403",
"Station longitude": "-24.86752",
"Station altitude": "10.0 m",
"Measurement altitude": "17.5 m",
"Measurement height": "7.5 m",
"Regime": "IMG",
"Component": "sulphur_dioxide",
"Matrix": "air",
"Laboratory code": "GB12L",
"Instrument type": "uv_fluoresc",
"Instrument name": "CVO_SO2_Thermo43series",
"Instrument manufacturer": "Thermo",
"Instrument model": "43i-TLE",
"Instrument serial number": "1170050157",
"Method ref": "GB12L_Thermo",
"Inlet type": "Hat or hood",
"Inlet description": "13m heated glass sampling inlet (40mm diameter) (residence time 4 secs), then 2m of 1/4\" teflon tubing at a flow rate of 1.8 L/min, then through a ss particulate filter (1-2micron) before it enters the instrument.",
"Inlet tube inner diameter": "40.0 mm",
"Inlet tube length": "15.0 m",
"Maintenance description": "The inlet filter is replaced annually. Pump membranes are replaced when needed. External zeros are done every 30 minutes. Linear calibrations monthly.",
"Flow rate": "1.8 l/min",
"Zero/span check type": "manual",
"Humidity/temperature control": "None",
"Organization": "GB12L, National Centre for Atmospheric Science, NCAS, , Department of Chemistry, University of York, YO10 5DD, York, United Kingdom",
"Framework acronym": "GAW-WDCRG",
"Framework name": "World Data Centre for Reactive Gases",
"Framework description": "The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Read, Katie, katie.read@ncas.ac.uk, National centre for Atmospheric Science, NCAS, WACL, University of York, Heslington, YO10 5DD, York, United Kingdom",
"Submitter": "Read, Katie, katie.read@ncas.ac.uk, National centre for Atmospheric Science, NCAS, WACL, University of York, Heslington, YO10 5DD, York, United Kingdom",
"Acknowledgement": "In the event of publications using this data the author must contact the Atmospheric Measurement Facility (AMF), part of the National Centre for Atmospheric Science (NCAS)."
}
|