citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Agia Marina Xyliatou / Cyprus Atmospheric Observatory (CY0002R) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/CY0002R.20150101000000.20191220122401.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.2y.1h.CY05L_Magee_AE31_CAO.CY05L_aethalometer_AE31_control_lev0_0_0_1.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "CY0002R.20150101000000.20191220122401.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.2y.1h.CY05L_Magee_AE31_CAO.CY05L_aethalometer_AE31_control_lev0_0_0_1.lev2.nc",
"File creation": "20191220192623",
"Startdate": "20150101000000",
"Revision date": "20191220122401",
"Version": "1",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "CY0002R",
"Platform code": "CY0002S",
"Station name": "Agia Marina Xyliatou / Cyprus Atmospheric Observatory",
"Station WDCA-ID": "GAWACY__CYP",
"Station GAW-ID": "CYP",
"Station GAW-Name": "Cyprus Atmospheric Observatory",
"Station land use": "Agricultural",
"Station setting": "Rural",
"Station GAW type": "R",
"Station WMO region": "6",
"Station latitude": "35.0381",
"Station longitude": "33.0578",
"Station altitude": "520.0 m",
"Measurement latitude": "35.04",
"Measurement longitude": "33.06",
"Measurement altitude": "532.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "CY05L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "Magee_AE31_CAO",
"Instrument manufacturer": "Magee",
"Instrument model": "AE31",
"Method ref": "CY05L_aethalometer_AE31_control_lev0_0_0_1",
"Standard method": "SOP=GAW227",
"Inlet type": "Hat or hood",
"Humidity/temperature control": "None",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument noise characteristics, no detection limit flag used",
"Measurement uncertainty": "25.0 %",
"Measurement uncertainty expl.": "Intercomparisons with thermo-optical analysis have shown an uncertainty of a faktor 2 regardless specific absorption cross-section assumed.",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"QA1 measure ID": "WCCAP-AP-2016-1",
"QA1 date": "20160311",
"QA1 document URL": "http://actris-ecac.eu/files/ECAC_report-AP-2016-1-3_the-cyprus-institute_AE31-1050-1009.pdf",
"Organization": "CY05L, The Cyprus Institute, CyI, \"Facility for Chemical Analyses (FCA), Energy, Environment and Water Research Center (EEWRC)\", P.O. Box 27456, , 1645, Nicosia, Cyprus",
"Frameworks": "GAW-WDCA",
"Originator": "Pikridas, Michael, m.pikridas@cyi.ac.cy, The Cyprus Institute, CyI-EEWRC, Energy Environment and Water Research Center, 20 Konstantinou Kavafi Street, \"2121, Aglantzia\", , Nicosia, Cyprus",
"Submitter": "Stavroulas, Iasonas, stajas@gmail.com, University of Crete, UoC, Department of Chemistry, P.O Box 2208, Voutes, 71003, Heraklion Crete, Greece",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "calibration factor / mean ratio=0.8; sample_spot_area=1.924e-5 m2"
}
|