citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Ústí n.L.-mesto (CZ0006B) using smps
- dates:
- fileIdentifier:
- EBAS/CZ0006B.20120501000000.20140703000000.smps.particle_number_size_distribution.pm10.11mo.1h.CZ05L_SMPS_CHMI_Usti.DE16L_EndVal_TROPOS-SMPS_v.1.1.4.21.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "CZ0006B.20120501000000.20140703000000.smps.particle_number_size_distribution.pm10.11mo.1h.CZ05L_SMPS_CHMI_Usti.DE16L_EndVal_TROPOS-SMPS_v.1.1.4.21.lev2.nc",
"File creation": "20190513103423",
"Startdate": "20120501000000",
"Revision date": "20140703000000",
"Version": "1",
"Version description": "initial revision, EndVal_TROPOS-SMPS v.1.1.4.21",
"Data level": "2",
"Period code": "11mo",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "CZ0006B",
"Platform code": "CZ0006S",
"Station name": "Ústí n.L.-mesto",
"Station latitude": "50.66109",
"Station longitude": "14.04029",
"Station altitude": "147.0 m",
"Measurement latitude": "50.66",
"Measurement longitude": "14.05",
"Measurement altitude": "218.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "CZ05L",
"Instrument type": "smps",
"Instrument name": "SMPS_CHMI_Usti",
"Instrument manufacturer": "TROPOS",
"Instrument model": "TROPOS-SMPS",
"Instrument serial number": "SMPS_Usti",
"Method ref": "DE16L_EndVal_TROPOS-SMPS_v.1.1.4.21",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Impactor--direct",
"Inlet description": "PM1 cyclone, flow 16.67 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer (1/4\" in diameter)",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "CZ05L, UNKNOWN, , , , , , , ",
"Originator": "Placha, Helena, placha@chmi.cz, Czech Hydrometeorological Institute, , Usti nad Labem Regional Office, Kockovska 18, Usti nad Labem, 400 11, , Czech Republic",
"Submitter": "Bitter, Miroslav, bitter@chmi.cz, Czech Hydrometeorological Institute, , Usti nad Labem Regional Office, Kockovska 18, Usti nad Labem, 400 11, , Czech Republic",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|