citation |
- title:
- Ground based in situ observations of steel_canister at Waldhof (DE0002R)
- dates:
- fileIdentifier:
- EBAS/DE0002R.20190103115500.20201211060000.steel_canister..air.1y.84h.DE03L_UBA_Wa_AuC_0001.DE28L_UBA_Sm_GCF_0001.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "DE0002R.20190103115500.20201211060000.steel_canister..air.1y.84h.DE03L_UBA_Wa_AuC_0001.DE28L_UBA_Sm_GCF_0001.lev2.nc",
"File creation": "2020-12-17T11:26:10.545719 UTC",
"Export state": "2020-12-17T10:25:03.130000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20190103115500",
"Revision date": "20201211060000",
"Version": "1",
"Version description": "initial revision, automatically generated, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "1y",
"Resolution code": "84h",
"Sample duration": "5mn",
"Orig. time res.": "5mn",
"Station code": "DE0002R",
"Platform code": "DE0002S",
"Station name": "Waldhof",
"Station latitude": "52.802222",
"Station longitude": "10.759444",
"Station altitude": "74.0 m",
"Measurement height": "7.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "DE03L",
"Instrument type": "steel_canister",
"Instrument name": "UBA_Wa_AuC_0001",
"Instrument manufacturer": "Riemer",
"Instrument model": "AUTOCAN 2_4",
"Analytical laboratory code": "DE28L",
"Analytical measurement technique": "GC",
"Analytical instrument name": "UBA_Sm_GCF_0001",
"Analytical instrument manufacturer": "PerkinElmer",
"Analytical instrument model": "Clarus 580",
"Method ref": "DE28L_UBA_Sm_GCF_0001",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Detection limit": "5.0 pmol/mol",
"Detection limit expl.": "Estimated, values below detection limit are flagged with 780.",
"Measurement uncertainty expl.": "Not determined",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Values below 1 ppt are not reported by the instrument.",
"Organization": "DE03L, Umweltbundesamt, UBA-LA, Langen, Paul-Ehrlich-Str. 29, , 63225, Langen, Germany",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Bryan, Hellack, bryan.hellack@uba.de, Umweltbundesamt Langen, UBA, Air Monitoring Network, Paul-Ehrlich-Str. 29, , 63225, Langen, Germany",
"Submitter": "Feigenspan, Stefan, stefan.feigenspan@uba.de, Umweltbundesamt, UBA, Air Quality Assessment, Woerlitzer Platz 1, , 06844, Dessau-Rosslau, Germany",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|