citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Zugspitze-Schneefernerhaus (DE0054R) using smps
- dates:
- fileIdentifier:
- EBAS/DE0054R.20190101000000.20200423000000.smps.particle_number_size_distribution.pm10.1y.1h.DE08L_TROPOS_SMPS_UBA_ZUGSPITZE.DE08L_TROPOS_2019.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "DE0054R.20190101000000.20200423000000.smps.particle_number_size_distribution.pm10.1y.1h.DE08L_TROPOS_SMPS_UBA_ZUGSPITZE.DE08L_TROPOS_2019.lev2.nc",
"File creation": "20200423102722",
"Startdate": "20190101000000",
"Revision date": "20200423000000",
"Version": "1",
"Version description": "initial revision, DMPS_control_lev2 v.0.0_1",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "10mn",
"Station code": "DE0054R",
"Platform code": "DE0054S",
"Station name": "Zugspitze-Schneefernerhaus",
"Station WDCA-ID": "GAWADE__ZSF",
"Station GAW-ID": "ZSF",
"Station GAW-Name": "Zugspitze-Schneefernerhaus",
"Station land use": "Gravel and stone",
"Station setting": "Mountain",
"Station GAW type": "G",
"Station WMO region": "6",
"Station latitude": "47.4165",
"Station longitude": "10.97964",
"Station altitude": "2671.0 m",
"Measurement latitude": "47.41",
"Measurement longitude": "10.98",
"Measurement altitude": "2650.0 m",
"Measurement height": "18.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "DE08L",
"Instrument type": "smps",
"Instrument name": "TROPOS_SMPS_UBA_ZUGSPITZE",
"Instrument manufacturer": "TROPOS",
"Instrument model": "TROPOS-SMPS",
"Instrument serial number": "TROPOS-SMPS-Zugspitze",
"Method ref": "DE08L_TROPOS_2019",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Open conductive tubing",
"Inlet description": "ambient humidity inlet without cyclone, flow 12 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer (1/4\" in diameter)",
"Volume std. temperature": "instrument internal",
"Volume std. pressure": "instrument internal",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012. (AMT)",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"QA1 measure ID": "WCCAP-MPSS-2019-2",
"QA1 date": "20190524",
"QA1 document URL": "https://www.actris-ecac.eu/files/ECAC-report-MPSS-2019-2-3.pdf",
"Organization": "DE08L, Leibniz Institute for Tropospheric Research, TROPOS, , Permoserstrasse 15, , 04318, Leipzig, Germany",
"Frameworks": "ACTRIS GAW-WDCA GUAN",
"Originator": "Tuch, Thomas, tuch@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, Experimental Aerosol and Cloud Microphysics, Permoserstr.15, , 04318, Leipzig, Germany",
"Submitter": "Tuch, Thomas, tuch@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, Experimental Aerosol and Cloud Microphysics, Permoserstr.15, , 04318, Leipzig, Germany",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|