citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Dresden-Winckelmannstrasse (DE0064B) using smps
- dates:
- fileIdentifier:
- EBAS/DE0064B.20150101000000.20160927000000.smps.particle_number_size_distribution.pm10.1y.1h.DE08L_SMPS_LfULG_Dresden-Winckelmannstrasse.DE08L_EndVal_TROPOS-SMPS_v.1.1.4.15.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "DE0064B.20150101000000.20160927000000.smps.particle_number_size_distribution.pm10.1y.1h.DE08L_SMPS_LfULG_Dresden-Winckelmannstrasse.DE08L_EndVal_TROPOS-SMPS_v.1.1.4.15.lev2.nc",
"File creation": "20191016023139",
"Startdate": "20150101000000",
"Revision date": "20160927000000",
"Version": "1",
"Version description": "initial revision, EndVal_TROPOS-SMPS v.1.1.4.15",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "DE0064B",
"Platform code": "DE0064S",
"Station name": "Dresden-Winckelmannstrasse",
"Station latitude": "51.036111",
"Station longitude": "13.730556",
"Station altitude": "120.0 m",
"Measurement latitude": "51.04",
"Measurement longitude": "13.73",
"Measurement altitude": "112.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "DE08L",
"Instrument type": "smps",
"Instrument name": "SMPS_LfULG_Dresden-Winckelmannstrasse",
"Instrument manufacturer": "TROPOS",
"Instrument model": "TROPOS-SMPS",
"Instrument serial number": "SMPS_Dresden-Winckelmannstrasse",
"Method ref": "DE08L_EndVal_TROPOS-SMPS_v.1.1.4.15",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, flow 16.67 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer (1/4\" in diameter)",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "DE08L, Leibniz Institute for Tropospheric Research, TROPOS, , Permoserstrasse 15, , 04318, Leipzig, Germany",
"Frameworks": "GUAN",
"Originator": "Wiedensohler, Alfred, alfred.wiedensohler@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, , Permoserstrasse 15, , 04318, Leipzig, Germany",
"Submitter": "Merkel, Maik, maik.merkel@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, , Permoserstrasse 15, , 04318, Leipzig, Germany",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Unknown uncertainty for D under 19.6 nm."
}
|