citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Leipzig-Eisenbahnstrasse (DE0066K) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/DE0066K.20160101010000.20210216000000.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.5y.1h.DE08L_MAAP-5012_LEE.DE08L_TROPOS_abs_coef.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "DE0066K.20160101010000.20210216000000.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.5y.1h.DE08L_MAAP-5012_LEE.DE08L_TROPOS_abs_coef.lev2.nc",
"File creation": "2021-04-20T11:04:00.871733 UTC",
"Export state": "2021-04-20T09:25:03.890000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20160101010000",
"Revision date": "20210216000000",
"Data level": "2",
"Period code": "5y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "DE0066K",
"Platform code": "DE0066S",
"Station name": "Leipzig-Eisenbahnstrasse",
"Station latitude": "51.345833",
"Station longitude": "12.406389",
"Station altitude": "120.0 m",
"Measurement latitude": "51.34",
"Measurement longitude": "12.37",
"Measurement altitude": "111.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "DE08L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "MAAP-5012_LEE",
"Instrument manufacturer": "Thermo",
"Instrument model": "5012",
"Method ref": "DE08L_TROPOS_abs_coef",
"Standard method": "Single-angle_Correction=none",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient temperature, flow 16.67 l/min",
"Humidity/temperature control": "Diffusion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with Diffusion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.1 1/Mm",
"Detection limit expl.": "Determined by instrument noise characteristics, no detection limit flag used",
"Measurement uncertainty": "6.0 %",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "DE08L, Leibniz Institute for Tropospheric Research, TROPOS, , Permoserstrasse 15, , 04318, Leipzig, Germany",
"Originator": "Wiedensohler, Alfred, ali@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, Experimental Aerosol and Cloud Microphysics, Permoserstr.15, , 04318, Leipzig, Germany",
"Submitter": "Tuch, Thomas, tuch@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, Experimental Aerosol and Cloud Microphysics, Permoserstr.15, , 04318, Leipzig, Germany",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|