citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Leipzig-Eisenbahnstrasse (DE0066K) using tdmps
- dates:
- fileIdentifier:
- EBAS/DE0066K.20170101000000.20200429000000.tdmps.particle_number_size_distribution.pm10.3y.1h.DE08L_TROPOS_TDMPS_LE_EISENBAHNSTRASSE.DE08L_TROPOS_CL_DMPS.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "DE0066K.20170101000000.20200429000000.tdmps.particle_number_size_distribution.pm10.3y.1h.DE08L_TROPOS_TDMPS_LE_EISENBAHNSTRASSE.DE08L_TROPOS_CL_DMPS.lev2.nc",
"File creation": "20201001182726",
"Startdate": "20170101000000",
"Revision date": "20200429000000",
"Version": "1",
"Version description": "initial revision, SMPS_control_lev1 v.0.0_1",
"Data level": "2",
"Period code": "3y",
"Resolution code": "1h",
"Orig. time res.": "10mn",
"Station code": "DE0066K",
"Platform code": "DE0066S",
"Station name": "Leipzig-Eisenbahnstrasse",
"Station latitude": "51.345833",
"Station longitude": "12.406389",
"Station altitude": "120.0 m",
"Measurement latitude": "51.34",
"Measurement longitude": "12.38",
"Measurement altitude": "111.0 m",
"Measurement height": "18.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "DE08L",
"Instrument type": "tdmps",
"Instrument name": "TROPOS_TDMPS_LE_EISENBAHNSTRASSE",
"Instrument manufacturer": "TROPOS",
"Instrument model": "TROPOS-TDMPS",
"Instrument serial number": "TDMPS-LE-Eisenbahnstrasse",
"Method ref": "DE08L_TROPOS_CL_DMPS",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, flow 16.67 l/min",
"Humidity/temperature control": "Diffusion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with Diffusion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012. (AMT)",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "DE08L, Leibniz Institute for Tropospheric Research, TROPOS, , Permoserstrasse 15, , 04318, Leipzig, Germany",
"Frameworks": "ACTRIS GUAN",
"Originator": "Tuch, Thomas, tuch@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, Experimental Aerosol and Cloud Microphysics, Permoserstr.15, , 04318, Leipzig, Germany",
"Submitter": "Tuch, Thomas, tuch@tropos.de, Leibniz Institute for Tropospheric Research, TROPOS, Experimental Aerosol and Cloud Microphysics, Permoserstr.15, , 04318, Leipzig, Germany",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|