citation |
- title:
- Ground based in situ observations of filter_3pack at Villum Research Station, Station Nord (DK0010G)
- dates:
- fileIdentifier:
- EBAS/DK0010G.20181225040000.20200513000000.filter_3pack..aerosol.2w.1w.DK01L_f3p_10.DK01L_ATAIR_01.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "DK0010G.20181225040000.20200513000000.filter_3pack..aerosol.2w.1w.DK01L_f3p_10.DK01L_ATAIR_01.lev2.nc",
"File creation": "2021-01-18T11:27:32.303678 UTC",
"Export state": "2021-01-18T10:25:04.943000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20181225040000",
"Revision date": "20200513000000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "2w",
"Resolution code": "1w",
"Sample duration": "1w",
"Orig. time res.": "1w",
"Station code": "DK0010G",
"Platform code": "DK0010S",
"Station name": "Villum Research Station, Station Nord",
"Station latitude": "81.6",
"Station longitude": "-16.67",
"Station altitude": "20.0 m",
"Measurement altitude": "1.0 m",
"Measurement height": "3.0 m",
"Regime": "IMG",
"Matrix": "aerosol",
"Laboratory code": "DK01L",
"Instrument type": "filter_3pack",
"Instrument name": "f3p_10",
"Instrument manufacturer": "Custom build - Leckel",
"Instrument model": "modified SEQ47/50 three stage open face",
"Instrument serial number": "9635",
"Analytical laboratory code": "DK01L",
"Analytical measurement technique": "IC",
"Analytical instrument name": "ATAIR_01",
"Analytical instrument manufacturer": "Dionex",
"Analytical instrument model": "ICS-2000",
"Method ref": "DK01L_ATAIR_01",
"Standard method": "SOP=EMEP_manual_v1996",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing",
"Flow rate": "34.7222222222 l/min",
"Medium": "Teflon",
"Sample preparation": "Water extraction after ultrasonic treatment",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter kept at ambient conditions together with sampling head.",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of field blanks",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"Organization": "DK01L, National Environmental Research Institute, NERI, , \"P.O.Box 358, Fredriksborgvei 399, DK-4000 Roskilde, Denmark\", , , , ",
"Framework acronym": "CAMP, EMEP_preliminary",
"Framework name": "OSPARCOM - Comprehensive Atmospheric Monitoring Programme, Preliminary data submissions for European Monitoring and Evaluation Programme",
"Framework description": "The OSPARCOM Comprehensive Atmospheric Monitoring Programme goal is the assessment of the atmospheric input of selected contaminants to the OSPAR maritime area and regions., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Wenche Aas, Kjetil Tørseth",
"Framework contact email": "waa@nilu.no, kt@nilu.no",
"Originator": "Nøjgaard, Jacob Klenø, jakn@envs.au.dk, Aarhus Universitet, ATAIR, ENVIS, Frederiksborgvej 399, Postbox 358, 4000, Roskilde, Denmark",
"Submitter": "Keller, Rune, , , , , , , , , ",
"Acknowledgement": "nobody"
}
|