citation |
- title:
- Ground based in situ observations of high_vol_sampler at Granada (ES0020U)
- dates:
- fileIdentifier:
- EBAS/ES0020U.20171202070000.20181126132000.high_vol_sampler..pm10.3mo.4d.ES08L_HVS_MCV_UGR_pm10.ES05L_OCEC_Sunset_IDAEA.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "ES0020U.20171202070000.20181126132000.high_vol_sampler..pm10.3mo.4d.ES08L_HVS_MCV_UGR_pm10.ES05L_OCEC_Sunset_IDAEA.lev2.nc",
"File creation": "2021-04-16T00:28:16.292016 UTC",
"Export state": "2021-04-15T23:25:04.580000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20171202070000",
"Revision date": "20181126132000",
"Version": "1",
"Data level": "2",
"Period code": "3mo",
"Resolution code": "4d",
"Sample duration": "1d",
"Orig. time res.": "4d",
"Station code": "ES0020U",
"Platform code": "ES0020S",
"Station name": "Granada",
"Station latitude": "37.164",
"Station longitude": "-3.605",
"Station altitude": "680.0 m",
"Measurement latitude": "37.164",
"Measurement longitude": "-3.605",
"Measurement altitude": "680.0 m",
"Regime": "IMG",
"Unit": "ug C/m3",
"Matrix": "pm10",
"Laboratory code": "ES08L",
"Instrument type": "high_vol_sampler",
"Instrument name": "HVS_MCV_UGR_pm10",
"Instrument manufacturer": "MCV",
"Instrument model": "CAV-A/MSb",
"Method ref": "ES05L_OCEC_Sunset_IDAEA",
"Standard method": "SOP=EMEP_manual_v2014, TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Inlet description": "Upward facing with rain shield",
"Medium": "Quartz",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "None",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "LOD provided by the instrumental manufacturer was used",
"Measurement uncertainty expl.": "Measurement uncertainty includes quantifiable uncertainty",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"Organization": "ES08L, \"University of Granada, CEAMA\", , , \"Avda. del Mediterraneo s/n, 18006 Granada, Spain\", , , , ",
"Framework acronym": "ACTRIS, CAMPAIGN, COLOSSAL, GAW-WDCA, NOAA-ESRL",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, , Chemical On-Line cOmpoSition and Source Apportionment of fine aerosoL, World Data Centre for Aerosols, ",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., , Assessment of fine atmospheric aerosols (PM2.5), ther spatial variability (across Europe), their temporal variability (1h or better), the seasonality, the phenomenology (chemical composition) and the sources., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme., ",
"Framework contact name": "Cathrine Lund Myhre, Wenche Aas, Wenche Aas, Markus Fiebig, Markus Fiebig",
"Framework contact email": "clm@nilu.no, waa@nilu.no, waa@nilu.no, Markus.Fiebig@nilu.no, Markus.Fiebig@nilu.no",
"Originator": "Titos, Gloria, , , , , , , , , ",
"Submitter": "Titos, Gloria, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|