citation |
- title:
- Ground based in situ observations of smps at Madrid (ES0021U)
- dates:
- fileIdentifier:
- EBAS/ES0021U.20140101000000.20150831000000.smps...4mo.1h.ES09L_TSI_3936_CIE1.ES09L_smps_01.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "ES0021U.20140101000000.20150831000000.smps...4mo.1h.ES09L_TSI_3936_CIE1.ES09L_smps_01.lev2.nc",
"File creation": "2021-05-27T16:44:02.993845 UTC",
"Export state": "2021-05-27T15:25:03.447000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20140101000000",
"Revision date": "20150831000000",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "4mo",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "270s",
"Station code": "ES0021U",
"Platform code": "ES0021S",
"Station name": "Madrid",
"Station latitude": "40.456436",
"Station longitude": "-3.725631",
"Station altitude": "669.0 m",
"Measurement latitude": "40.456436",
"Measurement longitude": "-3.725631",
"Measurement altitude": "669.0 m",
"Measurement height": "3.0 m",
"Regime": "IMG",
"Laboratory code": "ES09L",
"Instrument type": "smps",
"Instrument name": "TSI_3936_CIE1",
"Instrument manufacturer": "TSI",
"Instrument model": "3936",
"Instrument serial number": "70838465",
"Method ref": "ES09L_smps_01",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "The sampling line is a 4.5-m long, 1/4 inch diameter pipe with a weatherproof inlet to prevent rain to enter.",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer operated with reduced pressure sheath air",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Measurement uncertainty expl.": "The CPC counting efficiency curve was determined in 2013 following Wiedensohler et al 2012. Comparing with other CPCs, the particle number conc. measured had a deviation between 2.5 and 10% compared with the average value of all the CPCs.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "ES09L, \"Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Spain\", , , , , , , ",
"Framework acronym": "ACTRIS, GAW-WDCA",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, World Data Centre for Aerosols",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Cathrine Lund Myhre, Markus Fiebig",
"Framework contact email": "clm@nilu.no, Markus.Fiebig@nilu.no",
"Originator": "Artinano, Begona, b.artinano@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Environment Department, Av. Complutense 40, , E-28040, Madrid, Spain",
"Submitter": "Alonso-Blanco, Elisabeth, elisabeth.alonso@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Environment Department, Av. Complutense 40, , E-28040, Madrid, Spain",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "The system was checked for sample and sheath flows in a regular base,also for the high-voltage supply. Some latex calibrations were performed along the year to check the correct whole instrument operation."
}
|