citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Madrid (ES0021U) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/ES0021U.20200101000000.20220211070000.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.1y.1h.ES09L_Magee_AE33_55_CIEMAT.ES09L_abs_coef_AE33_ciemat_2019.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "ES0021U.20200101000000.20220211070000.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.1y.1h.ES09L_Magee_AE33_55_CIEMAT.ES09L_abs_coef_AE33_ciemat_2019.lev2.nc",
"File creation": "2022-03-08T17:51:31.491869 UTC",
"Export state": "2022-03-08T17:25:02.793000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20200101000000",
"Revision date": "20220211070000",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1s",
"Station code": "ES0021U",
"Platform code": "ES0021S",
"Station name": "Madrid",
"Station latitude": "40.456436",
"Station longitude": "-3.725631",
"Station altitude": "669.0 m",
"Measurement latitude": "40.456436",
"Measurement longitude": "-3.725631",
"Measurement altitude": "669.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "ES09L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "Magee_AE33_55_CIEMAT",
"Instrument manufacturer": "Magee",
"Instrument model": "AE33",
"Instrument serial number": "AE33-S00-00055",
"Method ref": "ES09L_abs_coef_AE33_ciemat_2019",
"Standard method": "Single-angle_Correction=Drinovec2015",
"Inlet type": "Hat or hood",
"Inlet description": "PM10 cut-off size vertical inlet (BGI, MiniPM® Inlet)",
"Flow rate": "5.0 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "Active, Sample Airstream Dryer - Nafion Membrane including external pump",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Adapted from manufacturer specification",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "ES09L, \"Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Spain\", , , , , , , ",
"Framework acronym": "ACTRIS",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.",
"Framework contact name": "Cathrine Lund Myhre",
"Framework contact email": "clm@nilu.no",
"Originator": "Fernandez, Javier, Javier.FernandezG@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Departamento de Medio Ambiente, Avenida Complutense 40, , 28040, Madrid, Spain",
"Submitter": "Fernandez, Javier, Javier.FernandezG@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Departamento de Medio Ambiente, Avenida Complutense 40, , 28040, Madrid, Spain",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Mass Absorption Cross-sections used in the calculations were those given by the manufacturer."
}
|