citation |
- title:
- Ground based in situ observations of nephelometer at Madrid (ES0021U)
- dates:
- fileIdentifier:
- EBAS/ES0021U.20210101000000.20220504120000.nephelometer..pm10.1y.1h.ES09L_Aurora_3000_CIEMAT.ES09L_scat_coef_Aurora3000_ciemat.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "ES0021U.20210101000000.20220504120000.nephelometer..pm10.1y.1h.ES09L_Aurora_3000_CIEMAT.ES09L_scat_coef_Aurora3000_ciemat.lev2.nc",
"File creation": "2022-05-05T16:27:40.923902 UTC",
"Export state": "2022-05-05T16:25:03.140000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20210101000000",
"Revision date": "20220504120000",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "ES0021U",
"Platform code": "ES0021S",
"Station name": "Madrid",
"Station latitude": "40.456436",
"Station longitude": "-3.725631",
"Station altitude": "669.0 m",
"Measurement latitude": "40.456436",
"Measurement longitude": "-3.725631",
"Measurement altitude": "669.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "ES09L",
"Instrument type": "nephelometer",
"Instrument name": "Aurora_3000_CIEMAT",
"Instrument manufacturer": "Ecotech",
"Instrument model": "Aurora3000",
"Instrument serial number": "12-1441",
"Method ref": "ES09L_scat_coef_Aurora3000_ciemat",
"Standard method": "cal-gas=CO2+AIR_truncation-correction=none",
"Inlet type": "Hat or hood",
"Inlet description": "PM10 cut-off size vertical inlet (BGI, MiniPM® Inlet)",
"Flow rate": "5.0 l/min",
"Humidity/temperature control": "Heating to 40% RH, limit 40 deg. C",
"Humidity/temperature control description": "passive, Heating to 40% RH, sample heated by the instrument if RH>40%",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "0.5 1/Mm",
"Measurement uncertainty expl.": "average value taken from Mueller et al., 2011 for statistical and calibration uncertainty",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"QA1 measure ID": "WCCAP-IN-2020-1",
"QA1 date": "2020-01-27 UTC",
"QA1 document URL": "https://www.actris-ecac.eu/files/ECAC-report-IN-2020-1-2.pdf",
"Organization": "ES09L, \"Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Spain\", , , , , , , ",
"Framework acronym": "ACTRIS",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.",
"Framework contact name": "Cathrine Lund Myhre",
"Framework contact email": "clm@nilu.no",
"Originator": "Fernandez, Javier, Javier.FernandezG@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Departamento de Medio Ambiente, Avenida Complutense 40, , 28040, Madrid, Spain",
"Submitter": "Fernandez, Javier, Javier.FernandezG@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Departamento de Medio Ambiente, Avenida Complutense 40, , 28040, Madrid, Spain",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Muller et al., 2011 values used for truncation correction"
}
|