citation |
- title:
- Ground based in situ observations of cpc at Madrid (ES0021U)
- dates:
- fileIdentifier:
- EBAS/ES0021U.20210101000000.20220530100000.cpc...1y.1h.ES09L_TSI_3772CEN_CIE1.ES09L_cpc_01.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "ES0021U.20210101000000.20220530100000.cpc...1y.1h.ES09L_TSI_3772CEN_CIE1.ES09L_cpc_01.lev2.nc",
"File creation": "2022-07-05T16:27:49.204222 UTC",
"Export state": "2022-07-05T16:25:04.157000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20210101000000",
"Revision date": "20220530100000",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "ES0021U",
"Platform code": "ES0021S",
"Station name": "Madrid",
"Station latitude": "40.456436",
"Station longitude": "-3.725631",
"Station altitude": "669.0 m",
"Measurement latitude": "40.456436",
"Measurement longitude": "-3.725631",
"Measurement altitude": "669.0 m",
"Measurement height": "3.5 m",
"Regime": "IMG",
"Laboratory code": "ES09L",
"Instrument type": "cpc",
"Instrument name": "TSI_3772CEN_CIE1",
"Instrument manufacturer": "TSI",
"Instrument model": "3772",
"Instrument serial number": "3772162801",
"Method ref": "ES09L_cpc_01",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "PM2.5 at ambient humidity inlet, Thermo Scientific, flow 16 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer operated with reduced pressure sheath air",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"QA1 measure ID": "WCCAP-CPC-2017-6",
"QA1 date": "2017-11-13 UTC",
"QA1 document URL": "http://www.actris-ecac.eu/files/ECAC-report-CPC-2017-6-2.pdf",
"Organization": "ES09L, \"Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Spain\", , , , , , , ",
"Framework acronym": "ACTRIS",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.",
"Framework contact name": "Cathrine Lund Myhre",
"Framework contact email": "clm@nilu.no",
"Originator": "Artinano, Begona, b.artinano@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Environment Department, Av. Complutense 40, , E-28040, Madrid, Spain",
"Submitter": "Alonso-Blanco, Elisabeth, elisabeth.alonso@ciemat.es, Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Environment Department, Av. Complutense 40, , E-28040, Madrid, Spain",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Concentration corrected to calibrated flow, coincidence correction applied"
}
|