citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Montseny (ES1778R) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/ES1778R.20130101000000.20160822072344.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.1y.1h.ES05L_Magee_Aethalometer_AE31.ES05L_aethalometer_AE31.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "ES1778R.20130101000000.20160822072344.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.1y.1h.ES05L_Magee_Aethalometer_AE31.ES05L_aethalometer_AE31.lev2.nc",
"File creation": "20190513134815",
"Startdate": "20130101000000",
"Revision date": "20160822072344",
"Version": "2",
"Version description": "initial revision data as provided by the instrument -- Processing lev0-lev1: process_lev0_lev1_AE31 V.1.00.02 -- Processing lev1-lev2: process_lev1_lev2_general V.1.00.02",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "ES1778R",
"Platform code": "ES1778S",
"Station name": "Montseny",
"Station latitude": "41.766667",
"Station longitude": "2.35",
"Station altitude": "700.0 m",
"Measurement latitude": "41.46",
"Measurement longitude": "2.21",
"Measurement altitude": "720.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "ES05L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "Magee_Aethalometer_AE31",
"Instrument manufacturer": "Magee",
"Instrument model": "AE31",
"Method ref": "ES05L_aethalometer_AE31",
"Standard method": "SOP=GAW227",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 Partisol, flow 16.7 l/min, connected to dryer and splitter",
"Humidity/temperature control": "Nafion dryer with temperature conditioning at 30 deg. C",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument noise characteristics, no detection limit flag used",
"Measurement uncertainty": "25.0 %",
"Measurement uncertainty expl.": "Intercomparisons with thermo-optical analysis have shown an uncertainty of a faktor 2 regardless specific absorption cross-section assumed.",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "ES05L, Institute of Environmental Assessment and Water Research, IDAEA-CSIC, , Jordi Girona 18-26, , 08034, Barcelona, Spain",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Alastuey, Andras, andras.alastuey@idaea.csic.es, , IDAEA, CSIC, C/ Jordi Girona 18-26, , 08034, Barcelona, Spain",
"Submitter": "Pandolfi, Marco, , , , , , , , , ",
"Comment": "calibration factor / mean ratio=1.0;sample_spot_area=0.5 cm2 (standard range)"
}
|