citation |
- title:
- Ground based in situ observations of nephelometer at Montseny (ES1778R)
- dates:
- fileIdentifier:
- EBAS/ES1778R.20140101000000.20160922082832.nephelometer..pm10.1y.1h.ES05L_Ecotech_Aurora_3000.ES05L_neph_control_lev2.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "ES1778R.20140101000000.20160922082832.nephelometer..pm10.1y.1h.ES05L_Ecotech_Aurora_3000.ES05L_neph_control_lev2.lev2.nc",
"File creation": "20190513134920",
"Startdate": "20140101000000",
"Revision date": "20160922082832",
"Version": "2",
"Version description": "Initial revision; Data corrected for T and P; Scattering corrected for truncation; manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "ES1778R",
"Platform code": "ES1778S",
"Station name": "Montseny",
"Station latitude": "41.766667",
"Station longitude": "2.35",
"Station altitude": "700.0 m",
"Measurement latitude": "41.46",
"Measurement longitude": "2.21",
"Measurement altitude": "720.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "ES05L",
"Instrument type": "nephelometer",
"Instrument name": "Ecotech_Aurora_3000",
"Instrument manufacturer": "Ecotech",
"Instrument model": "Aurora3000",
"Instrument serial number": "09-0867",
"Method ref": "ES05L_neph_control_lev2",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 Partisol, flow 16.7 l/min, connected to dryer and splitter",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument noise characteristics",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "ES05L, Institute of Environmental Assessment and Water Research, IDAEA-CSIC, , Jordi Girona 18-26, , 08034, Barcelona, Spain",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Alastuey, Andres, , , , , , , , , ",
"Submitter": "Pandolfi, Marco, , , , , , , , , ",
"Comment": "Scattering correction for truncation as in Muller et al. (2011). Standard Method cal-gas CO2,Scattering corrected for truncation. Humidity temperatur controll - Naflon dryer, Heating to 40% RH"
}
|