citation |
- title:
- Ground based in situ observations of particle_number_concentration at Montseny (ES1778R) using cpc
- dates:
- fileIdentifier:
- EBAS/ES1778R.20160101000000.20200914090658.cpc.particle_number_concentration.pm10.1y.1h.ES05L_TSI3776_MSY.ES05L_TSI3776.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "ES1778R.20160101000000.20200914090658.cpc.particle_number_concentration.pm10.1y.1h.ES05L_TSI3776_MSY.ES05L_TSI3776.lev2.nc",
"File creation": "20200914102936",
"Startdate": "20160101000000",
"Revision date": "20200914090658",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "ES1778R",
"Platform code": "ES1778S",
"Station name": "Montseny",
"Station latitude": "41.766667",
"Station longitude": "2.35",
"Station altitude": "700.0 m",
"Measurement latitude": "41.46",
"Measurement longitude": "2.21",
"Measurement altitude": "724.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "particle_number_concentration",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "ES05L",
"Instrument type": "cpc",
"Instrument name": "TSI3776_MSY",
"Instrument manufacturer": "TSI",
"Instrument model": "3776",
"Instrument serial number": "70902145",
"Method ref": "ES05L_TSI3776",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, Partisol, flow 16.7 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "sample dried to below 40% RH with nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "5.0 %",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "ES05L, Institute of Environmental Assessment and Water Research, IDAEA-CSIC, , Jordi Girona 18-26, , 08034, Barcelona, Spain",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Perez, Noemi, , , , , , , , , ",
"Submitter": "Perez, Noemi, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Concentration is not corrected to measured flow"
}
|