citation |
- title:
- Ground based in situ observations of organic_carbon at Montseny (ES1778R) using high_vol_sampler
- dates:
- fileIdentifier:
- EBAS/ES1778R.20160102000000.20200522000000.high_vol_sampler.organic_carbon.pm10.3y.4d.ES05L_HVS_DIGITEL_MSY_pm10.ES05L_OCEC_Sunset_IDAEA.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "ES1778R.20160102000000.20200522000000.high_vol_sampler.organic_carbon.pm10.3y.4d.ES05L_HVS_DIGITEL_MSY_pm10.ES05L_OCEC_Sunset_IDAEA.lev2.nc",
"File creation": "20200622182642",
"Startdate": "20160102000000",
"Revision date": "20200522000000",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "3y",
"Resolution code": "4d",
"Sample duration": "1d",
"Orig. time res.": "4d",
"Station code": "ES1778R",
"Platform code": "ES1778S",
"Station name": "Montseny",
"Station latitude": "41.766667",
"Station longitude": "2.35",
"Station altitude": "700.0 m",
"Measurement latitude": "41.779503",
"Measurement longitude": "2.357893",
"Measurement altitude": "724.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "organic_carbon",
"Unit": "ug C/m3",
"Matrix": "pm10",
"Laboratory code": "ES05L",
"Instrument type": "high_vol_sampler",
"Instrument name": "HVS_DIGITEL_MSY_pm10",
"Instrument manufacturer": "DIGITEL",
"Instrument model": "DHA-80",
"Method ref": "ES05L_OCEC_Sunset_IDAEA",
"Standard method": "SOP=EMEP_manual_v2014, TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Inlet description": "Upward facing with rain shield",
"Medium": "Quartz",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "Temperature controlled",
"Humidity/temperature control description": "air conditioning, filters kept inside conditioned room",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "LOD provided by the instrumental manufacturer was used",
"Measurement uncertainty expl.": "Measurement uncertainty includes quantifiable uncertainty",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"Organization": "ES05L, Institute of Environmental Assessment and Water Research, IDAEA-CSIC, , Jordi Girona 18-26, , 08034, Barcelona, Spain",
"Frameworks": "ACTRIS EMEP GAW-WDCA",
"Originator": "Perez, Noemi, , , , , , , , , ",
"Submitter": "Perez, Noemi, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|