citation |
- title:
- Ground based in situ observations of dmps at Utö (FI0009R)
- dates:
- fileIdentifier:
- EBAS/FI0009R.20070101000000.20220131092211.dmps...14y.1h.FI01L_FMI_DMPS_UTO.FI01L_dmps.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FI0009R.20070101000000.20220131092211.dmps...14y.1h.FI01L_FMI_DMPS_UTO.FI01L_dmps.lev2.nc",
"File creation": "2022-01-31T17:40:38.554732 UTC",
"Export state": "2022-01-31T17:25:03.127000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20070101000000",
"Revision date": "20220131092211",
"Version": "1",
"Version description": "initial revision, DMPS_control_lev0 v.0.0_1",
"Data level": "2",
"Period code": "14y",
"Resolution code": "1h",
"Sample duration": "1h",
"Station code": "FI0009R",
"Platform code": "FI0009S",
"Station name": "Utö",
"Station latitude": "59.779167",
"Station longitude": "21.377222",
"Station altitude": "7.0 m",
"Measurement latitude": "59.779167",
"Measurement longitude": "21.377222",
"Measurement altitude": "7.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Laboratory code": "FI01L",
"Instrument type": "dmps",
"Instrument name": "FMI_DMPS_UTO",
"Instrument manufacturer": "FMI",
"Instrument model": "FMI_DMPS_25",
"Method ref": "FI01L_dmps",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Cyclone",
"Inlet description": "TSP hat with PM2.5 cyclone",
"Humidity/temperature control": "Nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Negative values may appear in the data after inversion",
"Organization": "FI01L, Finnish Meteorological Institute, FMI, Atmospheric Composition Unit, Erik Palménin aukio, , FI-00560, Helsinki, Finland",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Hyvärinen, Antti, heikki.lihavainen@fmi.fi, Finnish Meteorological Institute, FMI, , Erik Palmenin aukio 1, , FI-00560, Helsinki, Finland",
"Submitter": "Kesti, Jutta, jutta.kesti@fmi.fi, Finnish Meteorological Institute, FMI, Atmospheric Composition, Erik Palmenin aukio 1, , FI-00560, Helsinki, Finland",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Particle losses due to nafion dryer have not taken into account"
}
|