citation |
- title:
- Ground based in situ observations of dmps at Hyytiälä (FI0050R)
- dates:
- fileIdentifier:
- EBAS/FI0050R.20130101000000.20220222151057.dmps...9y.1h.FI03L_UHEL_DMPS_HYY_01.FI03L__TRY_TDMPS.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FI0050R.20130101000000.20220222151057.dmps...9y.1h.FI03L_UHEL_DMPS_HYY_01.FI03L__TRY_TDMPS.lev2.nc",
"File creation": "2022-02-22T19:00:54.865768 UTC",
"Export state": "2022-02-22T17:21:54.170000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20130101000000",
"Revision date": "20220222151057",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "9y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "10mn",
"Station code": "FI0050R",
"Platform code": "FI0050S",
"Station name": "Hyytiälä",
"Station GAW-ID": "HYY",
"Station state/province": "Pirka",
"Station land use": "Forest",
"Station setting": "Rural",
"Station GAW type": "R",
"Station WMO region": "6",
"Station latitude": "61.85",
"Station longitude": "24.283333",
"Station altitude": "181.0 m",
"Measurement latitude": "61.847",
"Measurement longitude": "24.295",
"Measurement altitude": "179.0 m",
"Measurement height": "8.0 m",
"Regime": "IMG",
"Laboratory code": "FI03L",
"Instrument type": "dmps",
"Instrument name": "UHEL_DMPS_HYY_01",
"Instrument manufacturer": "UHEL",
"Instrument model": "DMPS_HYY_01",
"Instrument serial number": "00001",
"Method ref": "FI03L__TRY_TDMPS",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Hat or hood",
"Inlet description": "Ambient humidity inlet with rain cover, flow 150 l/min",
"Humidity/temperature control": "Diffusion dryer",
"Humidity/temperature control description": "sheath flow dried to below 40% RH, no aerosol flow drier",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Measurement uncertainty expl.": "uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "FI03L, University of Helsinki, UHEL, Institute for Atmospheric and Earth System Research (INAR), PO BOX 64, , FI-00014, University of Helsinki, Finland",
"Originator": "Petäjä, Tuukka, tuukka.petaja@helsinki.fi, University of Helsinki, UHEL, \"Division of Atmospheric Sciences, Department of Physics\", PO BOX 64, , FI-00014, University of Helsinki, Finland",
"Submitter": "Aalto, Pasi, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|