citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Pallas (Sammaltunturi) (FI0096G) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/FI0096G.20070101000000.20210324120358.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.13y.1h.FI01L_Thermo_5012_PAL.FI01L_maap_control_lev2_0_0_1.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FI0096G.20070101000000.20210324120358.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.13y.1h.FI01L_Thermo_5012_PAL.FI01L_maap_control_lev2_0_0_1.lev2.nc",
"File creation": "2021-03-24T17:49:09.561206 UTC",
"Export state": "2021-03-24T16:25:03.743000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20070101000000",
"Revision date": "20210324120358",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "13y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "FI0096G",
"Platform code": "FI0096S",
"Station name": "Pallas (Sammaltunturi)",
"Station WDCA-ID": "GAWAFI__PAL",
"Station GAW-ID": "PAL",
"Station GAW-Name": "Pallas",
"Station land use": "Forest",
"Station setting": "Rural",
"Station GAW type": "G",
"Station WMO region": "6",
"Station latitude": "67.973333333",
"Station longitude": "24.116111111",
"Station altitude": "565.0 m",
"Measurement latitude": "67.97361",
"Measurement longitude": "24.11583",
"Measurement altitude": "560.0 m",
"Measurement height": "7.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "FI01L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "Thermo_5012_PAL",
"Instrument manufacturer": "Thermo",
"Instrument model": "5012",
"Instrument serial number": "N/A",
"Method ref": "FI01L_maap_control_lev2_0_0_1",
"Standard method": "Multi-angle_Correction=Petzold2004",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, Rupprecht&Patachnik, flow 10 l/min",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "passive, sample heated from atmospheric to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.1 1/Mm",
"Detection limit expl.": "Determined by instrument noise characteristics, no detection limit flag used",
"Measurement uncertainty": "6.0 %",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "FI01L, Finnish Meteorological Institute, FMI, Atmospheric Composition Unit, Erik Palménin aukio, , FI-00560, Helsinki, Finland",
"Originator": "Backman, John, john.Backman@fmi.fi, Finnish Meteorological Institute, FMI, , Erik Palmenin aukio 1, , FI-00560, Helsinki, Finland",
"Submitter": "Backman, John, john.Backman@fmi.fi, Finnish Meteorological Institute, FMI, , Erik Palmenin aukio 1, , FI-00560, Helsinki, Finland",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "BC concentration are in standard temperature and pressure"
}
|