citation |
- title:
- Ground based in situ observations of online_gc at Pallas (Sammaltunturi) (FI0096G)
- dates:
- fileIdentifier:
- EBAS/FI0096G.20180101102800.20190515000000.online_gc..air.1y.1d.FI01L_Perkin_Elmer_GC_FID_SAM.FI01L_GC_FID_VOCAIR_Perkin_Elmer_SAM.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FI0096G.20180101102800.20190515000000.online_gc..air.1y.1d.FI01L_Perkin_Elmer_GC_FID_SAM.FI01L_GC_FID_VOCAIR_Perkin_Elmer_SAM.lev2.nc",
"File creation": "20200826102646",
"Startdate": "20180101102800",
"Revision date": "20190515000000",
"Version": "1",
"Version description": "Second revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1d",
"Sample duration": "30mn",
"Orig. time res.": "30mn",
"Station code": "FI0096G",
"Platform code": "FI0096S",
"Station name": "Pallas (Sammaltunturi)",
"Station WDCA-ID": "GAWAFI__PAL",
"Station GAW-ID": "PAL",
"Station GAW-Name": "Pallas",
"Station land use": "Forest",
"Station setting": "Rural",
"Station GAW type": "G",
"Station WMO region": "6",
"Station latitude": "67.973333333",
"Station longitude": "24.116111111",
"Station altitude": "565.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "FI01L",
"Instrument type": "online_gc",
"Instrument name": "Perkin_Elmer_GC_FID_SAM",
"Method ref": "FI01L_GC_FID_VOCAIR_Perkin_Elmer_SAM",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument counting Statistics, Detection limit flag used",
"Measurement uncertainty expl.": "Determined from partial uncertainties: measured uncertainties of calibration gas, sampling and analysis obtained from 5 sample runs, sampling flow from mass flow controller and standard deviation of blank values",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Zero and neg. values may not appear and they are replaced by the Detection limit value",
"Organization": "FI01L, Finnish Meteorological Institute, FMI, Atmospheric Composition Unit, Erik Palménin aukio, , FI-00560, Helsinki, Finland",
"Frameworks": "ACTRIS AMAP EMEP GAW-WDCRG",
"Originator": "Hakola, Hannele, , , , , , , , , ",
"Submitter": "Vestenius, Mika, mika.vestenius@fmi.fi, Finnish Meteorological Institute, FMI, Atmospheric Composion Unit, FMI, Erik Palménin aukio, FI-00560, Helsinki, Finland",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|