citation |
- title:
- Ground based in situ observations of high_vol_sampler at Revin (FR0009R)
- dates:
- fileIdentifier:
- EBAS/FR0009R.20180104090000.20210816090000.high_vol_sampler..pm25.9mo.6d.FR12L_Digitel_DA80_09.FR12L_ion_chromatography.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FR0009R.20180104090000.20210816090000.high_vol_sampler..pm25.9mo.6d.FR12L_Digitel_DA80_09.FR12L_ion_chromatography.lev2.nc",
"File creation": "2021-11-12T18:09:03.039476 UTC",
"Export state": "2021-11-12T17:25:03.373000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20180104090000",
"Revision date": "20210816090000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "9mo",
"Resolution code": "6d",
"Sample duration": "1d",
"Station code": "FR0009R",
"Platform code": "FR0009S",
"Station name": "Revin",
"Station latitude": "49.9",
"Station longitude": "4.633333",
"Station altitude": "390.0 m",
"Regime": "IMG",
"Matrix": "pm25",
"Laboratory code": "FR12L",
"Instrument type": "high_vol_sampler",
"Instrument name": "Digitel_DA80_09",
"Analytical laboratory code": "FR12L",
"Analytical measurement technique": "IC",
"Analytical instrument name": "ion_chromatography",
"Analytical instrument manufacturer": "Dionex",
"Analytical instrument model": "DX-600",
"Method ref": "FR12L_ion_chromatography",
"Inlet type": "Impactor--direct",
"Inlet description": "DIGITEL DPM2,5/30/00 pre-separator constructed as a 1-stage impactor",
"Flow rate": "500.0 l/min",
"Filter face velocity": "54.13 cm/s",
"Exposed filter area": "153.94 cm2",
"Filter description": "2500 QAT-UP diameter 150mm",
"Medium": "Quartz",
"Filter prefiring": "773.15 K, 24.0 h",
"Sample preparation": "Water extraction after ultrasonic treatment",
"Blank correction": "Blank corrected",
"Detection limit expl.": "Quantification limit, Determined by taking 3 times the method detection limit for analyte using 7 filters from the same batch",
"Organization": "FR07L, Institut Mines Telecom Lille Douai, IMT Lille Douai, SAGE department, 941 rue Charles Bourseul, CS 10838, 59508, Douai, France",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Sauvage, Stephane, , , , , , , , , ",
"Submitter": "Bourin, Aude, , , , , , , , , "
}
|