citation |
- title:
- Ground based in situ observations of steel_canister at Peyrusse Vieille (FR0013R)
- dates:
- fileIdentifier:
- EBAS/FR0013R.20170102120000.20180713000000.steel_canister..air.1y.84h.FR07L_MD-GC_NMHC_offline_FR13.FR07L_NMHC_analysis.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FR0013R.20170102120000.20180713000000.steel_canister..air.1y.84h.FR07L_MD-GC_NMHC_offline_FR13.FR07L_NMHC_analysis.lev2.nc",
"File creation": "20200923102740",
"Startdate": "20170102120000",
"Revision date": "20180713000000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "84h",
"Sample duration": "4h",
"Orig. time res.": "4h",
"Station code": "FR0013R",
"Platform code": "FR0013S",
"Station name": "Peyrusse Vieille",
"Station latitude": "43.616667",
"Station longitude": "0.183333",
"Station altitude": "200.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "FR07L",
"Instrument type": "steel_canister",
"Instrument name": "MD-GC_NMHC_offline_FR13",
"Instrument manufacturer": "Restek+Entech",
"Instrument model": "SilcoCan+Silonite",
"Instrument serial number": "580S13072901",
"Method ref": "FR07L_NMHC_analysis",
"Standard method": "SOP=GAW_204(2012)",
"Calibration scale": "NPL",
"Calibration standard ID": "NPL D09_0451",
"Secondary standard ID": "Manufacturer Air liquide_123489",
"Inlet type": "Stainless steel",
"Inlet description": "Primary line + manifold",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Analytical detection limit based on instrument noise, 3 time signal to noise ratio",
"Measurement uncertainty expl.": "Includes reproducibility (precision) + systematic errors (accuracy)",
"Zero/negative values code": "Zero possible",
"QA1 measure ID": "ACTRIS-VOC-1",
"QA1 date": "20120916",
"QA1 outcome": "pass",
"QA1 document name": "ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO GAW and EMEP observation networks",
"QA1 document date": "20150708",
"QA1 document URL": "https://doi.org/10.5194/amt-8-2715-2015",
"Organization": "FR07L, Ecole Nationale Supérieure des Mines de Douai, ENSMD, Département Sciences de l'Atmosphère et Génie de l'Environnement, 941 rue Charles Bourseul, CS 10838, 59508, Douai, France",
"Frameworks": "ACTRIS EMEP GAW-WDCRG",
"Originator": "Salameh, Therese, therese.salameh@mines-douai.fr, Ecole des Mines de Douai, EMD, SAGE Department, 941 rue Charles Bourseul, , F-59508, Douai, France",
"Submitter": "Sauvage, Stephane, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Silcosteel canisters, no dryer, no_ozone scrubber, calibration for each canister batch"
}
|