citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Pic du Midi (FR0019R) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/FR0019R.20170101000000.20180531125849.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.1y.1h.FR05L_filter_absorption_photometer_Magee_AE16.FR05L_Magee_AE16_PDM_ambient.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0019R.20170101000000.20180531125849.filter_absorption_photometer.aerosol_absorption_coefficient.aerosol.1y.1h.FR05L_filter_absorption_photometer_Magee_AE16.FR05L_Magee_AE16_PDM_ambient.lev2.nc",
"File creation": "20190514033650",
"Startdate": "20170101000000",
"Revision date": "20180531125849",
"Version": "1",
"Version description": "initial revision, raw data",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "15mn",
"Station code": "FR0019R",
"Platform code": "FR0019S",
"Station name": "Pic du Midi",
"Station latitude": "42.936667",
"Station longitude": "0.141944",
"Station altitude": "2877.0 m",
"Measurement latitude": "42.9372",
"Measurement longitude": "0.1411",
"Measurement altitude": "2877.0 m",
"Measurement height": "12.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "FR05L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "filter_absorption_photometer_Magee_AE16",
"Instrument manufacturer": "Magee",
"Instrument model": "AE16",
"Instrument serial number": "9003",
"Method ref": "FR05L_Magee_AE16_PDM_ambient",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Whole air inlet with size cut of 30 um (based on mean wind speed); Air temperature conditional warming system to defrost the hat when needed; isokinetic flux;",
"Humidity/temperature control": "Temperature controlled",
"Humidity/temperature control description": "sample heated to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.17 1/Mm",
"Detection limit expl.": "instrument characteristics, information from Magee Scientific",
"Measurement uncertainty expl.": "estimated due to lack of SOP",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "FR05L, Aerology Laboratory, , , \"PO Box 31400, Toulouse\", , , , ",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Meyerfeld, Yves, yves.meyerfeld@aero.obs-mip.fr, Observatoire Midi-Pyrenees, OMP, Laboratoire d'aerologie, 14 avenue Edouard Belin, , 31400, Toulouse, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment",
"Comment": "calibration factor / mean ratio=1.00; sample_spot_area=5e-5 m2 ; not corrected of the loading effect"
}
|