citation |
- title:
- Ground based in situ observations of ozone at SIRTA Atmospheric Research Observatory (FR0020R) using uv_abs
- dates:
- fileIdentifier:
- EBAS/FR0020R.20170101000000.20190429090438.uv_abs.ozone.air.2y.1h.FR01L_uv_abs_Teledyne_T400.FR01L_03_Teledyne_T400_GIF_ambient.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0020R.20170101000000.20190429090438.uv_abs.ozone.air.2y.1h.FR01L_uv_abs_Teledyne_T400.FR01L_03_Teledyne_T400_GIF_ambient.lev2.nc",
"File creation": "20190514033830",
"Startdate": "20170101000000",
"Revision date": "20190429090438",
"Version": "1",
"Version description": "initial revision",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "FR0020R",
"Platform code": "FR0020S",
"Station name": "SIRTA Atmospheric Research Observatory",
"Station latitude": "48.7086111111",
"Station longitude": "2.15888888889",
"Station altitude": "162.0 m",
"Measurement latitude": "48.709",
"Measurement longitude": "2.159",
"Measurement altitude": "162.0 m",
"Measurement height": "3.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "FR01L",
"Instrument type": "uv_abs",
"Instrument name": "uv_abs_Teledyne_T400",
"Instrument manufacturer": "Teledyne",
"Instrument model": "T400",
"Instrument serial number": "T400-320-S",
"Method ref": "FR01L_03_Teledyne_T400_GIF_ambient",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "6.35 mm",
"Inlet tube inner diameter": "3.96 mm",
"Inlet tube length": "1.0 m",
"Maintenance description": "inlet filter changed every 2 weeks, calibration yearly, pump is checked and replaced if needed once/year, ozone scrubber checked and replaced if needed once/year",
"Flow rate": "0.78 l/min",
"Zero/span check type": "manual",
"Zero/span check interval": "1d",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "sample heated from atmospheric to lab temperature",
"Detection limit expl.": "Determined by instrument counting statistics",
"Measurement uncertainty expl.": "Determined by standard deviation of measurements",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Absorption cross section": "1.1476e-17 cm2",
"Organization": "FR01L, \"Jean Sciare, LSCE\", , , \"Batiment 701, CEA Orme des Merisiers, 91191 Gif/Yvette, France\", , , , ",
"Frameworks": "ACTRIS EMEP",
"Originator": "Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|