citation |
- title:
- Ground based in situ observations of aerosol_light_scattering_coefficient at SIRTA Atmospheric Research Observatory (FR0020R) using nephelometer
- dates:
- fileIdentifier:
- EBAS/FR0020R.20170101000000.20200604131539.nephelometer.aerosol_light_scattering_coefficient.aerosol.1y.1h.FR01L_nephelometer_Ecotech_M9003_525nm.FR01L_Ecotech_M9003_GIF_ambient.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0020R.20170101000000.20200604131539.nephelometer.aerosol_light_scattering_coefficient.aerosol.1y.1h.FR01L_nephelometer_Ecotech_M9003_525nm.FR01L_Ecotech_M9003_GIF_ambient.lev2.nc",
"File creation": "20200604182824",
"Startdate": "20170101000000",
"Revision date": "20200604131539",
"Version": "1",
"Version description": "initial revision, raw not corrected data, no algorithm data treatment",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "FR0020R",
"Platform code": "FR0020S",
"Station name": "SIRTA Atmospheric Research Observatory",
"Station latitude": "48.7086111111",
"Station longitude": "2.15888888889",
"Station altitude": "162.0 m",
"Measurement latitude": "48.709",
"Measurement longitude": "2.159",
"Measurement altitude": "162.0 m",
"Measurement height": "6.0 m",
"Regime": "IMG",
"Component": "aerosol_light_scattering_coefficient",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "FR01L",
"Instrument type": "nephelometer",
"Instrument name": "nephelometer_Ecotech_M9003_525nm",
"Instrument manufacturer": "Ecotech",
"Instrument model": "M9003",
"Instrument serial number": "06-0511",
"Method ref": "FR01L_Ecotech_M9003_GIF_ambient",
"Standard method": "cal-gas=CO2+AIR_truncation-correction=Müller2011",
"Inlet type": "Hat or hood",
"Inlet description": "PM1 size cut-off ; Sample flow rate 5 l/min ; 4 meter stainless tube (1/2\" outside)",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "passive, sample heated from atmospheric to lab temperature, silica gel dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.3 1/Mm",
"Detection limit expl.": "instrument characteristics, information from Ecotech",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Truong, Francois, francois.truong@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment"
}
|