citation |
- title:
- Ground based in situ observations of online_gc at SIRTA Atmospheric Research Observatory (FR0020R)
- dates:
- fileIdentifier:
- EBAS/FR0020R.20170112100028.20181204000000.online_gc..air.50w.1d.FR01L_Perkin-Elmer-ATD300.FR01L_NMHC_analysis.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FR0020R.20170112100028.20181204000000.online_gc..air.50w.1d.FR01L_Perkin-Elmer-ATD300.FR01L_NMHC_analysis.lev2.nc",
"File creation": "20190514033829",
"Startdate": "20170112100028",
"Revision date": "20181204000000",
"Version": "2",
"Version description": "revision 1, manually inspected, peer reviewed",
"Data level": "2",
"Period code": "50w",
"Resolution code": "1d",
"Sample duration": "2h",
"Orig. time res.": "2h",
"Station code": "FR0020R",
"Platform code": "FR0020S",
"Station name": "SIRTA Atmospheric Research Observatory",
"Station latitude": "48.7086111111",
"Station longitude": "2.15888888889",
"Station altitude": "162.0 m",
"Measurement latitude": "48.709",
"Measurement longitude": "2.159",
"Measurement altitude": "162.0 m",
"Measurement height": "3.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "FR01L",
"Instrument type": "online_gc",
"Instrument name": "Perkin-Elmer-ATD300",
"Instrument manufacturer": "PerkinElmer+Varian+Varian",
"Instrument model": "ATD300+GC3800+Saturn MS2200",
"Method ref": "FR01L_NMHC_analysis",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few secondes",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "passive, sample heated from atmospheric to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "FR01L, \"Jean Sciare, LSCE\", , , \"Batiment 701, CEA Orme des Merisiers, 91191 Gif/Yvette, France\", , , , ",
"Frameworks": "ACTRIS",
"Originator": "Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "No SOP surrently available"
}
|