citation |
- title:
- Ground based in situ observations of organic_carbon at Observatoire Perenne de l'Environnement (FR0022R) using high_vol_sampler
- dates:
- fileIdentifier:
- EBAS/FR0022R.20170105090000.20191007143302.high_vol_sampler.organic_carbon.pm10.12mo.2d.FR11L_DIGITEL_DHA-80_OPE_pm10_ambient.FR11L_high_vol_sampler_DIGITEL_DHA-80.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FR0022R.20170105090000.20191007143302.high_vol_sampler.organic_carbon.pm10.12mo.2d.FR11L_DIGITEL_DHA-80_OPE_pm10_ambient.FR11L_high_vol_sampler_DIGITEL_DHA-80.lev2.nc",
"File creation": "20191008102832",
"Startdate": "20170105090000",
"Revision date": "20191007143302",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "12mo",
"Resolution code": "2d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "FR0022R",
"Platform code": "FR0022S",
"Station name": "Observatoire Perenne de l'Environnement",
"Station GAW-ID": "OPE",
"Station land use": "Agricultural",
"Station setting": "Rural",
"Station WMO region": "6",
"Station latitude": "48.5622222222",
"Station longitude": "5.50555555556",
"Station altitude": "392.0 m",
"Measurement latitude": "48.562",
"Measurement longitude": "5.505",
"Measurement altitude": "392.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "organic_carbon",
"Unit": "ug C/m3",
"Matrix": "pm10",
"Laboratory code": "FR11L",
"Instrument type": "high_vol_sampler",
"Instrument name": "DIGITEL_DHA-80_OPE_pm10_ambient",
"Instrument manufacturer": "DIGITEL",
"Instrument model": "DHA-80",
"Instrument serial number": "5020",
"Analytical laboratory code": "FR11L",
"Analytical measurement technique": "thermal-optical_analysis",
"Analytical instrument name": "SUNSET_French_1",
"Analytical instrument manufacturer": "Sunset Laboratory",
"Analytical instrument model": "OCEC Lab Instrument Model 5",
"Analytical instrument serial number": "150A",
"Method ref": "FR11L_high_vol_sampler_DIGITEL_DHA-80",
"Standard method": "SOP=EMEP_manual_v2014, TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 size cut-off",
"Flow rate": "493.5 l/min",
"Filter face velocity": "53.43 cm/s",
"Exposed filter area": "153.94 cm2",
"Filter description": "Tissuquartz 2500 QAT-UP 150mm",
"Medium": "Quartz",
"Filter prefiring": "773.15 K, 8.0 h",
"Filter conditioning": "None",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Artifact correction": "None",
"Charring correction": "By laser transmission",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter kept at ambient conditions together with sampling head",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of field blanks for TC and OC, limits given by manufacturer for EC",
"Measurement uncertainty expl.": "Measurement uncertainty as reported by the Sunset instrument",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values reported as measured if within detection limit, flagged with 147",
"QA1 measure ID": "ECAC-OCEC-2017-1",
"QA1 date": "20170301",
"QA1 document name": "Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC-2017-1)",
"QA1 document URL": "http://www.actris-ecac.eu/files/ECAC-report-OCEC-2017-1.pdf",
"QA2 measure ID": "ECAC-OCEC-2019-1",
"QA2 date": "20190301",
"QA2 document name": "Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC-2019-1)",
"QA2 document URL": "https://www.actris-ecac.eu/files/OCEC-2019-1-REPORT_final.pdf",
"Organization": "FR11L, Agence nationale pour la gestion des déchets radioactifs, Andra, , 1/7 rue Jean Monnet, , 92298, CHATENAY-MALABRY Cedex, France",
"Frameworks": "ACTRIS EMEP GAW-WDCA",
"Originator": "Vella, Anthony, Anthony.Vella@univ-grenoble-alpes.fr, Institut des Geosciences de l'Environnement, , , Chimie Atmospherique Neige et Glace, 460 rue de la piscine, F-38402, Saint-Martin d'Heres cedex, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment",
"Comment": "after prefiring, sample are packed in aluminum foil and sealed in plastic sheath before analysis"
}
|