citation |
- title:
- Ground based in situ observations of high_vol_sampler at Observatoire Perenne de l'Environnement (FR0022R)
- dates:
- fileIdentifier:
- EBAS/FR0022R.20180105090000.20210526062817.high_vol_sampler..pm25.1y.6d.FR11L_DIGITEL_DHA-80_OPE_pm25_ambient.FR11L_high_vol_sampler_DIGITEL_DHA-80.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FR0022R.20180105090000.20210526062817.high_vol_sampler..pm25.1y.6d.FR11L_DIGITEL_DHA-80_OPE_pm25_ambient.FR11L_high_vol_sampler_DIGITEL_DHA-80.lev2.nc",
"File creation": "2021-07-06T16:31:36.857594 UTC",
"Export state": "2021-07-06T15:25:02.730000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20180105090000",
"Revision date": "20210526062817",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "6d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "FR0022R",
"Platform code": "FR0022S",
"Station name": "Observatoire Perenne de l'Environnement",
"Station GAW-ID": "OPE",
"Station land use": "Agricultural",
"Station setting": "Rural",
"Station WMO region": "6",
"Station latitude": "48.5622222222",
"Station longitude": "5.50555555556",
"Station altitude": "392.0 m",
"Measurement latitude": "48.562",
"Measurement longitude": "5.505",
"Measurement altitude": "392.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "ug C/m3",
"Matrix": "pm25",
"Laboratory code": "FR11L",
"Instrument type": "high_vol_sampler",
"Instrument name": "DIGITEL_DHA-80_OPE_pm25_ambient",
"Instrument manufacturer": "DIGITEL",
"Instrument model": "DHA-80",
"Instrument serial number": "5020",
"Analytical laboratory code": "FR11L",
"Analytical measurement technique": "thermal-optical_analysis",
"Analytical instrument name": "SUNSET_French_1",
"Analytical instrument manufacturer": "Sunset Laboratory",
"Analytical instrument model": "OCEC Lab Instrument Model 5",
"Analytical instrument serial number": "150A",
"Method ref": "FR11L_high_vol_sampler_DIGITEL_DHA-80",
"Standard method": "SOP=EMEP_manual_v2014, TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Inlet description": "PM2.5 size cut-off",
"Flow rate": "485.5 l/min",
"Filter face velocity": "52.56 cm/s",
"Exposed filter area": "153.94 cm2",
"Filter description": "Tissuquartz 2500 QAT-UP 150mm",
"Medium": "Quartz",
"Filter prefiring": "773.15 K, 8.0 h",
"Filter conditioning": "None",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Artifact correction": "None",
"Charring correction": "By laser transmission",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter kept at ambient conditions together with sampling head",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of field blanks for TC and OC, limits given by manufacturer for EC",
"Measurement uncertainty expl.": "Measurement uncertainty as reported by the Sunset instrument",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values reported as measured if within detection limit, flagged with 147",
"QA1 measure ID": "ECAC-OCEC-2017-1",
"QA1 date": "2017-03-01 UTC",
"QA1 document name": "Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC-2017-1)",
"QA1 document URL": "http://www.actris-ecac.eu/files/ECAC-report-OCEC-2017-1.pdf",
"QA2 measure ID": "ECAC-OCEC-2019-1",
"QA2 date": "2019-03-01 UTC",
"QA2 document name": "Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC-2019-1)",
"QA2 document URL": "https://www.actris-ecac.eu/files/OCEC-2019-1-REPORT_final.pdf",
"Organization": "FR11L, Agence nationale pour la gestion des déchets radioactifs, Andra, , 1/7 rue Jean Monnet, , 92298, CHATENAY-MALABRY Cedex, France",
"Framework acronym": "ACTRIS, EMEP, GAW-WDCA",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig",
"Framework contact email": "clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no",
"Originator": "Vella, Anthony, Anthony.Vella@univ-grenoble-alpes.fr, Institut des Geosciences de l'Environnement, , , Chimie Atmospherique Neige et Glace, 460 rue de la piscine, F-38402, Saint-Martin d'Heres cedex, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment",
"Comment": "after prefiring, sample are packed in aluminum foil and sealed in plastic sheath before analysis"
}
|