citation |
- title:
- Ground based in situ observations of smps at Observatoire Perenne de l'Environnement (FR0022R)
- dates:
- fileIdentifier:
- EBAS/FR0022R.20200101000000.20220608073357.smps...4mo.1h.FR11L_smps_TSI_3936..lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0022R.20200101000000.20220608073357.smps...4mo.1h.FR11L_smps_TSI_3936..lev2.nc",
"File creation": "2022-06-08T16:36:01.160052 UTC",
"Export state": "2022-06-08T16:25:03.083000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20200101000000",
"Revision date": "20220608073357",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "4mo",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "FR0022R",
"Platform code": "FR0022S",
"Station name": "Observatoire Perenne de l'Environnement",
"Station GAW-ID": "OPE",
"Station land use": "Agricultural",
"Station setting": "Rural",
"Station WMO region": "6",
"Station latitude": "48.5622222222",
"Station longitude": "5.50555555556",
"Station altitude": "392.0 m",
"Measurement latitude": "48.562",
"Measurement longitude": "5.505",
"Measurement altitude": "392.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Laboratory code": "FR11L",
"Instrument type": "smps",
"Instrument name": "smps_TSI_3936",
"Instrument manufacturer": "TSI",
"Instrument model": "3936",
"Instrument serial number": "TBD",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Hat or hood",
"Inlet description": "Thermo scientific 12 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty expl.": "Uncertainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "negative values not possible",
"Organization": "FR11L, Agence nationale pour la gestion des déchets radioactifs, Andra, , 1/7 rue Jean Monnet, , 92298, CHATENAY-MALABRY Cedex, France",
"Framework acronym": "ACTRIS, GAW-WDCA",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, World Data Centre for Aerosols",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Cathrine Lund Myhre, Markus Fiebig",
"Framework contact email": "clm@nilu.no, Markus.Fiebig@nilu.no",
"Originator": "Conil, Sebastien, Sebastien.Conil@andra.fr, Observatoire Perenne de l'Environnement, ANDRA/OPE, Centre de Meuse/Haute-Marne, RD960, CP9, 55290, Bure, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment"
}
|