citation |
- title:
- Ground based in situ observations of aerosol_mass_spectrometer at Villeneuve d'Ascq (FR0027U)
- dates:
- fileIdentifier:
- EBAS/FR0027U.20161011000000.20201009113552.aerosol_mass_spectrometer..pm1_non_refractory.4y.1h.FR07L_Aerodyne_Q-ACSM_140-157.FR07L_Ng_2011.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "FR0027U.20161011000000.20201009113552.aerosol_mass_spectrometer..pm1_non_refractory.4y.1h.FR07L_Aerodyne_Q-ACSM_140-157.FR07L_Ng_2011.lev2.nc",
"File creation": "20201009182603",
"Startdate": "20161011000000",
"Revision date": "20201009113552",
"Version": "1",
"Version description": "File generated with EETA v2.6. Initial version, manually inspected.",
"Data level": "2",
"Period code": "4y",
"Resolution code": "1h",
"Orig. time res.": "30mn",
"Station code": "FR0027U",
"Platform code": "FR0027S",
"Station name": "Villeneuve d'Ascq",
"Station GAW-ID": "VDA",
"Station land use": "Other",
"Station setting": "Suburban",
"Station WMO region": "6",
"Station latitude": "50.611017",
"Station longitude": "3.14035",
"Station altitude": "70.0 m",
"Measurement height": "20.0 m",
"Regime": "IMG",
"Unit": "ug/m3",
"Matrix": "pm1_non_refractory",
"Laboratory code": "FR07L",
"Instrument type": "aerosol_mass_spectrometer",
"Instrument name": "Aerodyne_Q-ACSM_140-157",
"Instrument manufacturer": "Aerodyne",
"Instrument model": "Q-ACSM",
"Instrument serial number": "140-157",
"Method ref": "FR07L_Ng_2011",
"Standard method": "Ref=Ng_2011",
"Inlet type": "Cyclone",
"Inlet description": "Inlet cutpoint=PM2.5; Comment=",
"Humidity/temperature control": "Nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Measurement uncertainty expl.": "Uncertainties calculated using based on the method of Allan et al. (2003), DOI 10.1029/2002JD002358.",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "FR07L, Institut Mines Telecom Lille Douai, IMT Lille Douai, SAGE department, 941 rue Charles Bourseul, CS 10838, 59508, Douai, France",
"Frameworks": "ACTRIS COLOSSAL",
"Originator": "Riffault, Véronique, , Département Sciences de lAtmosphère et Génie de lEnvironnement, SAGE, , , Mines Douai, , Douai, France",
"Submitter": "Riffault, Véronique, , Département Sciences de lAtmosphère et Génie de lEnvironnement, SAGE, , , Mines Douai, , Douai, France",
"Acknowledgement": "EETA (EBAS Export Tool for ACSM/AMS) development was supported by ACTRIS. Request acknowledgement details from data originator. The EETA export tool was developed with support from ACTRIS."
}
|