citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Villeneuve d'Ascq (FR0027U) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/FR0027U.20210101000000.20220607150343.filter_absorption_photometer.aerosol_absorption_coefficient.pm1.1y.1h.FR07L_Magee_AE33_S02-00267_Lille.FR07L_AE33manual.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0027U.20210101000000.20220607150343.filter_absorption_photometer.aerosol_absorption_coefficient.pm1.1y.1h.FR07L_Magee_AE33_S02-00267_Lille.FR07L_AE33manual.lev2.nc",
"File creation": "2022-06-26T16:26:50.460846 UTC",
"Export state": "2022-06-26T16:25:02.863000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20210101000000",
"Revision date": "20220607150343",
"Version": "1",
"Version description": "initial revision, raw data",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "FR0027U",
"Platform code": "FR0027S",
"Station name": "Villeneuve d'Ascq",
"Station GAW-ID": "VDA",
"Station land use": "Other",
"Station setting": "Suburban",
"Station WMO region": "6",
"Station latitude": "50.611017",
"Station longitude": "3.14035",
"Station altitude": "70.0 m",
"Measurement latitude": "50.611",
"Measurement longitude": "3.1403",
"Measurement altitude": "90.0 m",
"Measurement height": "20.0 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "pm1",
"Laboratory code": "FR07L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "Magee_AE33_S02-00267_Lille",
"Instrument manufacturer": "Magee",
"Instrument model": "AE33",
"Instrument serial number": "AE33-S02-00267",
"Method ref": "FR07L_AE33manual",
"Standard method": "Single-angle_Correction=Drinovec2015",
"Inlet type": "Cyclone",
"Inlet description": "Vertical inlet stainless steel tubing and black conductive tubing from the manufacturer",
"Flow rate": "5.0 l/min",
"Humidity/temperature control": "Nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.1 1/Mm",
"Detection limit expl.": "instrument characteristics, information from Magee",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "zero and neg. values may appear due to statistical variations at very low concentrations; no zero values for channels 2, 6 and 7 (470, 880 and 950 nm)",
"Organization": "FR07L, Institut Mines Telecom Lille Douai, IMT Lille Douai, SAGE department, 941 rue Charles Bourseul, CS 10838, 59508, Douai, France",
"Framework acronym": "ACTRIS, GAW-WDCA",
"Framework name": "European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, World Data Centre for Aerosols",
"Framework description": "ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Cathrine Lund Myhre, Markus Fiebig",
"Framework contact email": "clm@nilu.no, Markus.Fiebig@nilu.no",
"Originator": "Brito, Joel, joel.brito@imt-nord-europe.fr, Ecole Nationale Superieure Mines-Telecom Lille Douai, IMT Lille Douai, Departement Sciences de l'Atmosphere et Genie de l'Environnement, 941 rue Charles Bourseul, CS 10838, 59508, Douai, France",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment",
"Comment": "calibration factor / mean ratio=7.77; sample_spot_area=7.85e-5 m2"
}
|