citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Puy de Dôme (FR0030R) using smps
- dates:
- fileIdentifier:
- EBAS/FR0030R.20150101000000.20200622161037.smps.particle_number_size_distribution.aerosol.2y.1h.FR04L_LAMP_SMPS_PDD.FR04L_SMPS_LaMP.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0030R.20150101000000.20200622161037.smps.particle_number_size_distribution.aerosol.2y.1h.FR04L_LAMP_SMPS_PDD.FR04L_SMPS_LaMP.lev2.nc",
"File creation": "20200622184649",
"Startdate": "20150101000000",
"Revision date": "20200622161037",
"Version": "1",
"Version description": "Initial version",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "150s",
"Station code": "FR0030R",
"Platform code": "FR0030S",
"Station name": "Puy de Dôme",
"Station GAW-ID": "PUY",
"Station land use": "Forest",
"Station setting": "Mountain",
"Station WMO region": "6",
"Station latitude": "45.772223",
"Station longitude": "2.964886",
"Station altitude": "1465.0 m",
"Measurement latitude": "45.772223",
"Measurement longitude": "2.964886",
"Measurement altitude": "1465.0 m",
"Measurement height": "12.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "aerosol",
"Laboratory code": "FR04L",
"Instrument type": "smps",
"Instrument name": "LAMP_SMPS_PDD",
"Instrument manufacturer": "CNRS-LaMP",
"Instrument model": "SMPSmodel1",
"Instrument serial number": "1",
"Method ref": "FR04L_SMPS_LaMP",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "Whole air inlet",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "sample dried by difference of temperature between external and internal conditions",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "30.0 %",
"Measurement uncertainty expl.": "Typical value of unit-to-unit variability",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "FR04L, CNRS-LaMP, , , Campus des Cézeaux, 24 avenue des Landais, 63177, Aubière, France",
"Originator": "Picard, David, d.picard@opgc.univ-bpclermont.fr, , , , , , , , ",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment"
}
|