citation |
- title:
- Ground based in situ observations of ozone at Puy de Dôme (FR0030R) using uv_abs
- dates:
- fileIdentifier:
- EBAS/FR0030R.20190101000000.20220419101747.uv_abs.ozone.air.3y.1h.FR04L_uv_abs_Thermo_49i.FR04L_Thermo_49i_PUY.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "FR0030R.20190101000000.20220419101747.uv_abs.ozone.air.3y.1h.FR04L_uv_abs_Thermo_49i.FR04L_Thermo_49i_PUY.lev2.nc",
"File creation": "2022-04-19T16:30:16.306896 UTC",
"Export state": "2022-04-19T16:25:03.097000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20190101000000",
"Revision date": "20220419101747",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "3y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "FR0030R",
"Platform code": "FR0030S",
"Station name": "Puy de Dôme",
"Station GAW-ID": "PUY",
"Station land use": "Forest",
"Station setting": "Mountain",
"Station WMO region": "6",
"Station latitude": "45.772223",
"Station longitude": "2.964886",
"Station altitude": "1465.0 m",
"Measurement latitude": "45.772223",
"Measurement longitude": "2.964886",
"Measurement altitude": "1465.0 m",
"Measurement height": "12.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "FR04L",
"Instrument type": "uv_abs",
"Instrument name": "uv_abs_Thermo_49i",
"Instrument manufacturer": "Thermo",
"Instrument model": "49i",
"Instrument serial number": "1152990091",
"Method ref": "FR04L_Thermo_49i_PUY",
"Standard method": "SOP=GAW_209(2013)",
"Inlet type": "Hat or hood",
"Inlet description": "upstream from manifold, tube length=6.5m, flow rate=17l/min",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "41.5 mm",
"Inlet tube inner diameter": "28.0 mm",
"Inlet tube length": "1.5 m",
"Maintenance description": "Monthly leak test, inlet filter checked every 2 months, ozone scrubber checked and replaced if needed once/year",
"Flow rate": "0.5 l/min",
"Zero/span check type": "manual",
"Zero/span check interval": "3mo",
"Humidity/temperature control": "Temperature conditioning at 20 deg. C",
"Humidity/temperature control description": "None",
"Absorption cross section": "1.1476e-17 cm2",
"Organization": "FR04L, CNRS-LaMP, , , Campus des Cézeaux, 24 avenue des Landais, 63177, Aubière, France",
"Framework acronym": "EMEP, GAW-WDCA",
"Framework name": "European Monitoring and Evaluation Programme, World Data Centre for Aerosols",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth, Markus Fiebig",
"Framework contact email": "kt@nilu.no, Markus.Fiebig@nilu.no",
"Originator": "Pichon, Jean-Marc, , , , , , , , , ",
"Submitter": "Pascal, Nicolas, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|