citation |
- title:
- Ground based in situ observations of online_gc at Auchencorth Moss (GB0048R)
- dates:
- fileIdentifier:
- EBAS/GB0048R.20180101000000.20220524000000.online_gc..air.4y.1h.GB02L_Perkin_Elmer_GC_FID.GB02L_HC_Data_Processing_WIs_8.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "GB0048R.20180101000000.20220524000000.online_gc..air.4y.1h.GB02L_Perkin_Elmer_GC_FID.GB02L_HC_Data_Processing_WIs_8.lev2.nc",
"File creation": "2022-05-30T16:29:58.019992 UTC",
"Export state": "2022-05-30T16:25:03.547000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20180101000000",
"Revision date": "20220524000000",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "4y",
"Resolution code": "1h",
"Sample duration": "40mn",
"Orig. time res.": "40mn",
"Station code": "GB0048R",
"Platform code": "GB0048S",
"Station name": "Auchencorth Moss",
"Station latitude": "55.79216",
"Station longitude": "-3.2429",
"Station altitude": "260.0 m",
"Measurement altitude": "260.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "GB02L",
"Instrument type": "online_gc",
"Instrument name": "Perkin_Elmer_GC_FID",
"Instrument manufacturer": "PerkinElmer+Varian+Varian",
"Instrument model": "ATD300+GC3800+Saturn MS2200",
"Instrument serial number": "650N5021501",
"Method ref": "GB02L_HC_Data_Processing_WIs_8",
"Standard method": "SOP=ACTRIS_VOC_2014",
"Calibration scale": "NPL",
"Calibration standard ID": "Manufacturer NPL; Batch D386645",
"Secondary standard ID": "Manufacturer NPL; Batch D641887R",
"Inlet type": "Hat or hood",
"Inlet description": "Wide PVCU pipe, ~laminar flow, residence time <1sec",
"Detection limit expl.": "Manufacturers quoted detection limit of 10pmol/mol",
"Measurement uncertainty expl.": "Follows ACTRIS_SOP",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Zero and neg. values are replaced by the Detection limit value",
"Organization": "GB02L, \"AEA Technology, National Environmental Techn. Centre\", , , \"Culham Abington, OXFORDSHIRE OX14 3DB, United Kingdom\", , , , ",
"Originator": "Fowler, Ben, ben.fowler@ricardo.com, Ricardo, REE, Energy & Environment, The Gemini Building, Fermi Avenue, OX11 0QR, Didcot, UK",
"Submitter": "Davies, Trevor, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Preconcentration TurboMatrix, no ozone scrubber, nafion dryer, 14 day calibration interval for 4 samples at 4nmol/mol"
}
|