citation |
- title:
- Ground based in situ observations of ads_tube at Auchencorth Moss (GB0048R)
- dates:
- fileIdentifier:
- EBAS/GB0048R.20220712120000.20221213000000.ads_tube..air.1w.1d.FR07L_OVOC_offline_gb48.FR07L_HPLC_OVOCs_analysis_IMP_2022.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Data license": "https://creativecommons.org/licenses/by/4.0/",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "GB0048R.20220712120000.20221213000000.ads_tube..air.1w.1d.FR07L_OVOC_offline_gb48.FR07L_HPLC_OVOCs_analysis_IMP_2022.lev2.nc",
"File creation": "2022-12-13T16:26:43.701624 UTC",
"Export state": "2022-12-13T16:25:03.421722 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20220712120000",
"Revision date": "20221213000000",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "1w",
"Resolution code": "1d",
"Sample duration": "4h",
"Station code": "GB0048R",
"Platform code": "GB0048S",
"Station name": "Auchencorth Moss",
"Station latitude": "55.79216",
"Station longitude": "-3.2429",
"Station altitude": "260.0 m",
"Regime": "IMG",
"Unit": "ug/m3",
"Matrix": "air",
"Laboratory code": "FR07L",
"Instrument type": "ads_tube",
"Instrument name": "OVOC_offline_gb48",
"Instrument manufacturer": "Waters",
"Instrument model": "Sep-Pak XPoSure Sampler WAT047205",
"Analytical laboratory code": "FR07L",
"Analytical measurement technique": "HPLC",
"Analytical instrument name": "HPLC_OVOCs_analysis_IMP_2022",
"Analytical instrument manufacturer": "Thermo Scientific",
"Analytical instrument model": "Ultimate 3000",
"Method ref": "FR07L_HPLC_OVOCs_analysis_IMP_2022",
"Standard method": "SOP=EMEP_manual_v2014",
"Detection limit expl.": "Analytical detection limit based on instrument noise, 3 time signal to noise ratio",
"Organization": "FR07L, Institut Mines Telecom Lille Douai, IMT Lille Douai, SAGE department, 941 rue Charles Bourseul, CS 10838, 59508, Douai, France",
"Framework acronym": "CAMPAIGN, EMEP",
"Framework name": ", European Monitoring and Evaluation Programme",
"Framework description": ", The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Wenche Aas, Kjetil Tørseth",
"Framework contact email": "waa@nilu.no, kt@nilu.no",
"Originator": "Salameh, Therese, therese.salameh@mines-douai.fr, Ecole des Mines de Douai, EMD, SAGE Department, 941 rue Charles Bourseul, , F-59508, Douai, France",
"Submitter": "Salameh, Therese, therese.salameh@mines-douai.fr, Ecole des Mines de Douai, EMD, SAGE Department, 941 rue Charles Bourseul, , F-59508, Douai, France",
"Comment": "Calibration standard Apel Riemer, blank systematically substracted"
}
|